C&S Electric - MRA-Pro-V2 - Trip Circuit Supervision Relay (Microprocessor)

C&S Electric - MRA-Pro-V2 - Trip Circuit Supervision Relay (Microprocessor)

About this product

The C&S Electric MRA-PRO-V2 is a numeric Trip Circuit Supervision Relay. A protection scheme is only as good as the wire between the trip contact and the trip coil, and that wire can fail silently - a broken coil, a loose terminal, a lost DC supply. Nobody finds out until the day a fault occurs and the breaker does not open. The MRA-PRO-V2 supervises the whole tripping route continuously, with the breaker closed or open.

Documents

Datasheet

C&S Electric - MRA-Pro-V2 - Trip Circuit Supervision Relay (Microprocessor)

Catalogue No:

MRA-Pro-V2

C&S Electric

₹6,600/ nosexcl. GST₹7,788 incl. 18% GST2 nos in stock
SKYC092Auxiliary Relay1 seller

Purchase information

Availability
In stock — 2 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362010 · GST 18% · price includes GST

Last updated:

Product Details

FieldValue
Product NameTrip Circuit Supervision Relay (Microprocessor)
BrandC&S Electric
Catalogue / Part NumberMRA-Pro-V2
SKUSKYC092
Product TypeAuxiliary Relay
MRP (excl. GST)₹6,600
Selling Price (excl. GST)₹6,600
Price incl. GST₹7,788
Discount-
GST Rate18%
HSN Code85362010
CurrencyINR
AvailabilityIn Stock
Quantity Available2 nos
Min Order Quantity1 nos
LocationBommanahalli
ParametersOrdering based Horizontal/Vertical cabinet, Microprocessor based
Supply24 V / 110 V / 220 V DC on terminals 1 (+ve) and 2 (-ve)
Breaking CapacityAC 1250 VA; DC resistive 0.4 A at 200 V DC
ANSI Codes74TC (trip circuit supervision)
Weight-
Volumetric Weight-
Dimensions (L × W × H)-
DatasheetView datasheet
Drawing / CAD-
Description
Input24 V / 110 V / 220 V DC; operative ranges 12-48 V, 55-180 V, 110-280 V; hysteresis 15 V DC
OutputPotential free for CB failure indication: 1 NO + 1 NC (model -00) or 2 NO + 2 NC (model -01)
Range
Price List Specification
Key Features
Applications
Technical Specs
Protection FunctionsContinuous trip-circuit supervision in pre-closing and post-closing conditions; trip-coil open/short detection; trip supply failure; CB contact failure
Standards ComplianceMicroprocessor based; type-test standards not printed in the C&S catalogue (Rev. 05, 07.01.25)

Frequently Asked Questions for C&S Electric MRA-Pro-V2 Auxiliary Relay

What are the key features of the C&S Electric MRA-Pro-V2 Auxiliary Relay?

The key features of the C&S Electric MRA-Pro-V2 are: Supervises the trip path with the breaker both closed and open, which a simple series lamp cannot do; Detects trip-coil open circuit, trip-coil short, low trip supply and CB contact failure; Settable 0.1 / 0.3 / 0.6 s delay avoids spurious alarms during normal CB operation; Auto or manual reset mode selected from the front panel; Built-in TEST function for routine maintenance without external injection; Four-LED status display - CB OK, CB Fail, Manual and Edit.

Where is the C&S Electric MRA-Pro-V2 Auxiliary Relay used?

The C&S Electric MRA-Pro-V2 is used for: Circuit-breaker trip-coil supervision in MV and HV substations; Feeder, generator, motor and transformer protection panels; Unmanned substations where a failed trip coil would otherwise go unnoticed; Retrofit supervision on breakers whose protection IED has no 74TC function.

What is the C&S Electric MRA-Pro-V2 Auxiliary Relay?

The C&S Electric MRA-Pro-V2 is the Trip Circuit Supervision Relay (Microprocessor). Trip Circuit Supervision Relay (MRA-Pro-V2) from C&S Electric.

What are the technical specifications of the C&S Electric MRA-Pro-V2 Auxiliary Relay?

The C&S Electric MRA-Pro-V2 technical specifications are: Trip circuit supervision: 24 V / 110 V / 220 V DC; operative ranges 12-48 V, 55-180 V, 110-280 V; hysteresis 15 V DC; Supervision time delay: 0.1 s / 0.3 s / 0.6 s user settable, accuracy +/- 30 ms; Auxiliary supply: 24 V / 110 V / 220 V DC on terminals 1 (+ve) and 2 (-ve); Output contacts: Potential free for CB failure indication: 1 NO + 1 NC (model -00) or 2 NO + 2 NC (model -01); Max breaking capacity: AC 1250 VA; DC resistive 0.4 A at 200 V DC; Max continuous current: 6 A at 230 V AC / 24 V DC; Inputs: CB Open DI and CB Close DI with DI common; Indication: 4 LEDs - CB OK, CB Fail, Manual, Edit; Operation modes: Auto (indication self-resets once the trip circuit is healthy) or Manual (held until RESET is pressed); Self test: TEST function - hold RESET while applying auxiliary supply; Dimensions: Front 144.00 x 76.00 mm; case body 68.00 mm wide; depth overall 147.00 mm, case 134.00 mm; panel cut-out 70.0 x 139.0 mm; Ordering code: MRA-PRO-V2-(24/110/220)-V-(00/01).

What protection functions does the C&S Electric MRA-Pro-V2 Auxiliary Relay provide?

The C&S Electric MRA-Pro-V2 provides: Continuous trip-circuit supervision in pre-closing and post-closing conditions; trip-coil open/short detection; trip supply failure; CB contact failure.

Which ANSI device codes does the C&S Electric MRA-Pro-V2 Auxiliary Relay cover?

The C&S Electric MRA-Pro-V2 covers ANSI device codes 74TC (trip circuit supervision).

Which standards does the C&S Electric MRA-Pro-V2 Auxiliary Relay comply with?

Standards and compliance for the C&S Electric MRA-Pro-V2: Microprocessor based; type-test standards not printed in the C&S catalogue (Rev. 05, 07.01.25).

Tags

  • MRA-Pro-V2
  • MRA-Pro-V2 C&S Electric
  • Trip Circuit Supervision Relay (Microprocessor) C&S Electric
  • Trip Circuit Supervision Relay (Microprocessor)
  • C&S Electric Auxiliary Relay
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?