C&S Electric - FDC1-V5-UO - Numerical DC Under & Over Voltage Relay

C&S Electric - FDC1-V5-UO - Numerical DC Under & Over Voltage Relay

About this product

The C&S Electric FDC1-V5 is a numerical DC Voltage Protection Relay for supervising station batteries, starter batteries and DC distribution systems. A station battery is the one supply that must never fail, because it is what trips the breakers when everything else does. A battery drifting low or a charger running high both shorten its life and compromise the protection that depends on it.

Documents

Datasheet

C&S Electric - FDC1-V5-UO - Numerical DC Under & Over Voltage Relay

Catalogue No:

FDC1-V5-UO

C&S Electric

₹20,000/ nosexcl. GST₹23,600 incl. 18% GST2 nos in stock
SKYC055DC Voltage Protection Relay1 seller

Purchase information

Availability
In stock — 2 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362010 · GST 18% · price includes GST

Last updated:

Product Details

FieldValue
Product NameNumerical DC Under & Over Voltage Relay
BrandC&S Electric
Catalogue / Part NumberFDC1-V5-UO
SKUSKYC055
Product TypeDC Voltage Protection Relay
MRP (excl. GST)₹20,000
Selling Price (excl. GST)₹20,000
Price incl. GST₹23,600
Discount-
GST Rate18%
HSN Code85362010
CurrencyINR
AvailabilityIn Stock
Quantity Available2 nos
Min Order Quantity1 nos
LocationBommanahalli
InputSet on the relay: 10-250 V in 1 V steps
OutputMax breaking capacity 250 V AC/DC at 5 A
ParametersFlush Mounting, Fixed
Supply
  • L: 20-150 V DC
  • H: 85-280 V AC / 110-300 V DC
Breaking CapacityMax breaking capacity 250 V AC/DC at 5 A
Weight-
Volumetric Weight-
Dimensions (L × W × H)-
DatasheetView datasheet
Drawing / CAD-
Description
RangeU> and U>> pickup 50-250% of Vr in 1% steps; definite time 0.1-60 s in 0.1 s steps
Price List Specification
Key Features
Applications
Technical Specs
ANSI Codes27DC / 59DC (DC under and over voltage) - standard designations; not printed by C&S
Protection FunctionsTwo-step DC over voltage (U>, U>>) and two-step DC under voltage (U<, U<<), each with separately adjustable pickup and definite time delay
Standards Compliance

Frequently Asked Questions for C&S Electric FDC1-V5-UO Protection Relay

What are the key features of the C&S Electric FDC1-V5-UO relay?

The key features of the C&S Electric FDC1-V5-UO are: Two independent stages per function, so alarm and trip levels can be set separately; Rated voltage is set in the relay from 10 to 250 V, covering every common station battery; Last five faults held in non-volatile memory with origin and measured DC voltage; Programmable assignment of both digital outputs, with auto or manual reset per output; Draw-out case - the relay can be withdrawn for testing without disturbing panel wiring; 12 x 2 LCD with live measurement display and IP-54 front dust cover.

Why choose the C&S Electric FDC1-V5-UO relay?

Choose the C&S Electric FDC1-V5-UO when your circuit needs DC over and under voltage protection. Check the settings range and output contacts in the C&S Electric datasheet against your protection scheme before ordering.

Where is the C&S Electric FDC1-V5-UO relay used?

The C&S Electric FDC1-V5-UO is used for: Supervision of station batteries in substations and power plants; Starter-battery monitoring on diesel generating sets; DC distribution boards and battery charger output supervision; Telecom and UPS DC bus monitoring; Any DC system where under-voltage would disable tripping or over-voltage would damage loads.

What is the difference between numerical, static and electromechanical protection relays?

Electromechanical relays operate with moving parts and offer limited adjustment. Static relays use analog electronics, usually for one protection function. Numerical relays are microprocessor-based, combine several protection functions in one unit, and usually add communication and event recording.

What are the technical specifications of the C&S Electric FDC1-V5-UO relay?

The C&S Electric FDC1-V5-UO technical specifications are: Technology: Numerical, micro-controller based; draw-out flush-mounted case; Rated voltage Vr: Set on the relay: 10-250 V in 1 V steps; Over voltage setting: U> and U>> pickup 50-250% of Vr in 1% steps; definite time 0.1-60 s in 0.1 s steps; Under voltage setting: U< and U<< pickup 30-125% of Vr in 1% steps; definite time 0.1-60 s in 0.1 s steps; Thermal withstand: Continuously 2 x Vr; Drop out to pickup ratio: > 97%; Returning time: 30 ms; Minimum response time: 30 ms; Operating value accuracy: +/- 5%; Operating time accuracy: +/- 5% or +/- 100 ms; Auxiliary supply: L: 20-150 V DC; H: 85-280 V AC / 110-300 V DC; Power consumption: Quiescent approx. 3 W; operating < 7 W; Digital outputs: 2 (DO1, DO2), relay type, programmable assignment, programmable auto/manual reset (default manual); Output relay rating: Max breaking capacity 250 V AC/DC at 5 A; Fault records: Last 5 faults in non-volatile memory with origin (under/over voltage) and DC voltage magnitude; Display: 12 x 2 bright LCD, 3 front push buttons, 4 annunciation LEDs (model dependent); Front protection: IP-54 transparent dust cover; Weight: Approx. 1.0 kg; Dimensions: Front 76.00 x 144.0 mm; case body 68.00 x 136.0 mm; depth 134.00 mm; panel cut-out 70.0 x 139.0 mm; Temperature (type test): Operational -20 C to 55 C; transport and storage -25 C to 70 C; Ordering code: FDC1-V5-(U/O/UO)-(L/H).

What protection functions does the C&S Electric FDC1-V5-UO relay provide?

The C&S Electric FDC1-V5-UO provides: Two-step DC over voltage (U>, U>>) and two-step DC under voltage (U<, U<<), each with separately adjustable pickup and definite time delay.

Which ANSI device codes does the C&S Electric FDC1-V5-UO relay cover?

The C&S Electric FDC1-V5-UO covers ANSI device codes 27DC / 59DC (DC under and over voltage) - standard designations; not printed by C&S.

Tags

  • FDC1-V5-UO
  • FDC1-V5-UO C&S Electric
  • Numerical DC Under & Over Voltage Relay C&S Electric
  • Numerical DC Under & Over Voltage Relay
  • C&S Electric Protection Relay
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?