C&S Electric - IRP-V3 - Under/Over/Reverse Power Protection Relay

About this product
The C&S Electric IRP-V3 is a numerical Directional Power Relay for reverse-power and forward active-power supervision in LV and MV systems. If the prime mover of a generator fails while the machine stays connected to the system, the alternator becomes a motor and starts driving the engine or turbine backwards. That is expensive: a steam turbine overheats its low-pressure blades in minutes, a diesel engine can be wrecked outright. The IRP-V3 recognises the change in power direction and disconnects the machine.
Documents
DatasheetC&S Electric
Purchase information
HSN 85362010 · GST 18% · price includes GST
Last updated:
| Field | Value |
|---|---|
| Product Name | Under/Over/Reverse Power Protection Relay |
| Brand | C&S Electric |
| Catalogue / Part Number | IRP-V3 |
| SKU | SKYC063 |
| Product Type | Generator & Power Protection Relay |
| MRP (excl. GST) | ₹20,000 |
| Selling Price (excl. GST) | ₹20,000 |
| Price incl. GST | ₹23,600 |
| Discount | - |
| GST Rate | 18% |
| HSN Code | 85362010 |
| Currency | INR |
| Availability | In Stock |
| Field | Value |
|---|---|
| Quantity Available | 2 nos |
| Min Order Quantity | 1 nos |
| Location | Bommanahalli |
| Input | 1 A or 5 A (model dependent) |
| Range | P< 2-100% Pn in 1% steps, definite time 0.2-200.0 s (default OFF) |
| Parameters | Flush Mount |
| Supply |
|
| Breaking Capacity | 5 A at 250 V AC or 30 V DC resistive (N/O); 2 A at 250 V AC or 30 V DC (N/C) |
| Weight | - |
| Volumetric Weight | - |
| Dimensions (L × W × H) | - |
| Datasheet | View datasheet |
| Drawing / CAD | - |
| Description | |
|---|---|
| Output | 1 C/O + 2 N/O; DO Matrix assigns any of the 3 DOs to any function including self supervision |
| Price List Specification | |
| Key Features | |
| Applications | |
| Technical Specs | |
| ANSI Codes | 32 (directional power / reverse power), with forward over-power and under-power elements |
| Protection Functions | Reverse power (Pr>), forward over power (P>) and forward under power (P<), each independent with separately adjustable pickup and definite time delay |
| Standards Compliance |
The key features of the C&S Electric IRP-V3 are: Three independent power elements - reverse, forward over and forward under - in one compact case; DO Matrix lets any of the three outputs be assigned to any function, including self supervision; Per-function automatic or manual reset selected from the HMI; Under-power detection level stops spurious pickup when the machine is simply off load; Built-in CT and PT ratio settings up to 6500 and 1000; Continuous metering of active power, voltage and current on the front LCD; Last five faults recorded with the measured values at the moment of trip.
Choose the C&S Electric IRP-V3 when your generator circuit needs generator protection. Check the settings range and output contacts in the C&S Electric datasheet against your protection scheme before ordering.
The C&S Electric IRP-V3 is used for: Reverse-power protection of turbo generators and diesel generating sets; Protecting the prime mover when a generator motors after the engine or turbine fails; Power-direction supervision of a generator running in parallel with the grid; Captive power plants and co-generation schemes; Interconnector and tie-line power-flow supervision.
Electromechanical relays operate with moving parts and offer limited adjustment. Static relays use analog electronics, usually for one protection function. Numerical relays are microprocessor-based, combine several protection functions in one unit, and usually add communication and event recording.
The C&S Electric IRP-V3 technical specifications are: Technology: Microprocessor based, compact SMD design; plastic IP54 flush-mounted case; Measuring principle: Load measured in one phase only, assuming symmetrically loaded phases; Rated voltage Un: 110 V / 230 V / 415 V AC (model dependent); Rated current In: 1 A or 5 A (model dependent); Frequency: Range 50 Hz +/- 2.5 Hz; rated 50 Hz; Under power setting: P< 2-100% Pn in 1% steps, definite time 0.2-200.0 s (default OFF); Over power setting: P> 2-150% Pn in 1% steps, definite time 0.2-200.0 s (default 110% Pn); Reverse power setting: Pr> 2-100% Pn in 1% steps, definite time 0.2-200.0 s (default 10% Pn); CT / PT ratio: CT ratio 1-6500; PT ratio 1-1000; Connection setting: L-N or L-L, set to match the connection diagram; Measurement accuracy: Active power +/- 2.5% over 2-150% Pn at rated frequency; Trip time accuracy: +/- 5% or +/- 100 ms, whichever is higher; Drop out to pickup ratio: > 96%; Auxiliary supply: L: 18-60 V DC; H: 85-280 V AC / 100-300 V DC; Aux power consumption: Quiescent approx. 1.6 W; operating approx. 2.0 W; Burden: Current circuit < 1 VA (0.2 VA at 1 A, 0.4 VA at 5 A); voltage circuit < 1 VA; Current thermal withstand: 100 x Ip for 1 s; 30 x Ip for 10 s; 4 x Ip continuous; Output contacts: 1 C/O + 2 N/O; DO Matrix assigns any of the 3 DOs to any function including self supervision; Contact rating: 5 A at 250 V AC or 30 V DC resistive (N/O); 2 A at 250 V AC or 30 V DC (N/C); Fault records: Last 5 faults in non-volatile memory with active power, voltage, current and fault type; Display: 12 x 2 LCD showing active power, voltage and current continuously; LEDs P>, P<, Pr> and TRIP; Temperature: Operation 0 C to 70 C; storage -10 C to 85 C; Weight: Approx. 700 g; Dimensions: Front 144 x 76 mm; case body 68 x 137.5 mm; depth overall 147 mm, case 134 mm; panel cut-out 70 x 139 mm; Ordering code: IRP-V3-(1/5)-(1/2/4)-(L/H).
The C&S Electric IRP-V3 provides: Reverse power (Pr>), forward over power (P>) and forward under power (P<), each independent with separately adjustable pickup and definite time delay.
The C&S Electric IRP-V3 covers ANSI device codes 32 (directional power / reverse power), with forward over-power and under-power elements.
Standards and compliance for the C&S Electric IRP-V3: IEC 60255 functional; IEC 60068-2-1/2-2 temperature; IEC 60255-21-1 shock; IEC 60068-2-6 vibration; IEC 60255-5 dielectric and insulation > 100 Mohm; IEC 61000-4-2/3/4/5/6 EMC; CISPR 11 emission; IEC 529 enclosure.
Yes, the C&S Electric IRP-V3 (Under/Over/Reverse Power Protection Relay) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.
You can buy C&S Electric protection relays online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with relay selection.
Yes, VendorStocks takes bulk and project-quantity orders for the C&S Electric IRP-V3. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.
Yes. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your quantity for a formal quotation on the C&S Electric IRP-V3, or add it to your cart and choose “Continue to Buy” to order directly. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.
Yes, the C&S Electric datasheet for the IRP-V3 can be downloaded from the Documents section of this product page.
Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.

C&S Electric - IRU-Pro-U - Numeric Under-Voltage Relay
₹13,000excl. GST₹15,340 incl. 18% GST

C&S Electric - IRI1-ES - Sensitive Earth Fault Relay
₹16,000excl. GST₹18,880 incl. 18% GST

C&S Electric - BU1-AC-U - 3 Phase Under Voltage Relay
₹9,000excl. GST₹10,620 incl. 18% GST

C&S Electric - CSEZEN-F-550X-4-N-D-O-H-A-0-E-H - Advance Feeder Relay F550X (4-N-D-O-H-A-0-E-H)
RFQ

C&S Electric - CSENEX-U200-1-1-H - Numerical Multifunction Feeder Relay U200 (Horizontal)
RFQ

C&S Electric - MRN2 - Numeric Combined Mains Decoupling Relay
₹1,60,000excl. GST₹1,88,800 incl. 18% GST
Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.
Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.
Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.
Your cart is empty
New Account
Create your account to continue
Already have an account?
Welcome back
Sign in to continue
Don't have an account?