ACB U-Power Omega 2500 A - 4 Pole, Manual Fixed, UW-MTX1G

UW225NFF01800 Lauritz Knudsen ACB U-Power Omega 2500 A - 4 Pole, Manual Fixed, UW-MTX1G

About this product

Lauritz Knudsen U-Power Omega air circuit breakers rated up to 690 V AC, covering 800 A to 4000 A in 3 pole and 4 pole versions at 50 kA breaking capacity at 415 V AC. Available in manual draw-out (MDO) and manual fixed (MF) versions. The UW-MTX1G release provides LSING protection - long time, short time, instantaneous, neutral and ground fault - set through BCD switches; the UW-MTX1.5G release adds current metering. A conversion kit is available to convert a manual draw-out breaker to electrical draw-out, or a manual fixed breaker to electrical fixed. Other release options including UW-MTX1.0, UW-MTX1Gi, UW-MTX1.5Gi, UW-MTX3.5, UW-MTX3.5EC, UW-MTX3.5H, UW-MTX4.5 and the new UW-MTX3.5T and UW-MTX3.5ET Ethernet variants are available on request. Conforms to IEC 60947-2.

UW225NFF01800 Lauritz Knudsen ACB U-Power Omega 2500 A - 4 Pole, Manual Fixed, UW-MTX1G

Lauritz Knudsen

UW225NFF01800
₹6,05,800/ nos5 nos in stock
SKYLK1316Air Circuit Breaker1 seller

Specifications

Operating Voltage
690 V AC
Poles
4
Rated Current
2500 A

Purchase information

Availability
In stock — 5 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362000 · GST 18% · price excludes GST

Product Details

FieldValue
Product NameACB U-Power Omega 2500 A - 4 Pole, Manual Fixed, UW-MTX1G
BrandLauritz Knudsen
Catalogue / Part NumberUW225NFF01800
SKUSKYLK1316
Product TypeAir Circuit Breaker
DescriptionAir circuit breaker, U-Power Omega series, rated 2500 A, 4 Pole, Manual Fixed (MF) version, breaking capacity Icu 50 kA at 415 V AC, suitable up to 690 V AC. Fitted with the UW-MTX1G release providing LSING protection with BCD switches. Standard packing 1 no. Catalogue number UW225NFF01800. Conforms to IEC 60947-2.
MRP₹6,05,800
Selling Price₹6,05,800
Discount-
GST Rate18%
HSN Code85362000
CurrencyINR
AvailabilityIn Stock
Quantity Available5 nos
Min Order Quantity1 nos
LocationBommanahalli
Input415 V AC (suitable up to 690 V AC)
Output-
Range2500 A
Parameters4 Pole, U-Power Omega series, Manual Fixed (MF) version, UW-MTX1G release providing LSING protection with BCD switches, IEC 60947-2
Supply-
Breaking CapacityIcu 50 kA at 415 V AC
Price List Specification-
Weight115 kg
Volumetric Weight123.75 kg
Dimensions (L × W × H)110 × 75 × 75 cm
Datasheet-
Drawing / CAD-

Frequently Asked Questions for Lauritz Knudsen UW225NFF01800 Air Circuit Breaker

What are the key features of the Lauritz Knudsen UW225NFF01800 air circuit breaker?

The Lauritz Knudsen UW225NFF01800 is a 4-pole air circuit breaker rated at 2500A with 50kA breaking capacity, in manual fixed construction. It belongs to the Lauritz Knudsen U-Power Omega range.

Where is the Lauritz Knudsen UW225NFF01800 air circuit breaker used?

The Lauritz Knudsen UW225NFF01800 is used as a main incomer, bus coupler or outgoing feeder breaker in LT main switchboards and power control centers (PCCs), including transformer and DG set incomers, for loads up to 2500A.

What accessories can be used with the Lauritz Knudsen UW225NFF01800 air circuit breaker?

Air circuit breakers are commonly fitted with a shunt release for remote tripping, an undervoltage release, a closing coil and motor operator for electrical operation, auxiliary contacts for status signalling, and mechanical interlocks and locking devices for safe operation. Check the Lauritz Knudsen accessory list for the UW225NFF01800 before ordering.

What is the difference between fixed and draw-out air circuit breakers?

A fixed ACB is bolted directly to the panel busbars, so it can only be removed with the panel switched off. A draw-out ACB sits in a cradle and can be racked out to the test or isolated position for maintenance and testing, and replaced quickly without disturbing the busbar connections.

How do I select the right air circuit breaker rating?

Select an ACB whose rated current, after derating for the panel’s internal ambient temperature (often 50 °C in Indian panels), is at least the maximum load current of the incomer — for a transformer incomer, the transformer full-load current (about 1.39 A per kVA at 415 V) — and whose breaking capacity (Icu, and preferably Ics) is at least the prospective short-circuit current at the switchboard. Where breakers must discriminate, also check that the short-time withstand rating (Icw) covers that fault current for the required time, usually 1 second.

Can I buy Lauritz Knudsen UW225NFF01800 air circuit breaker through VendorStocks?

Yes, the Lauritz Knudsen UW225NFF01800 (ACB U-Power Omega 2500 A - 4 Pole, Manual Fixed, UW-MTX1G) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.

Where is the best place to buy Lauritz Knudsen air circuit breakers online in India?

You can buy Lauritz Knudsen air circuit breakers online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with product selection.

Can I buy Lauritz Knudsen UW225NFF01800 air circuit breaker in bulk quantity from VendorStocks?

Yes, VendorStocks takes bulk and project-quantity orders for the Lauritz Knudsen UW225NFF01800. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.

Can I make an RFQ (Request for Quotation) for Lauritz Knudsen UW225NFF01800 air circuit breaker?

Yes. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your quantity for a formal quotation on the Lauritz Knudsen UW225NFF01800, or add it to your cart and choose “Continue to Buy” to order directly. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.

Can I get the technical datasheet for Lauritz Knudsen UW225NFF01800 air circuit breaker?

Yes, you can request the Lauritz Knudsen datasheet for the UW225NFF01800 from VendorStocks at +91 99021 83031 or support@skylightsenergy.in.

What payment methods are accepted on VendorStocks?

Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.

What are the detailed specifications of Lauritz Knudsen UW225NFF01800 air circuit breaker?

The Lauritz Knudsen UW225NFF01800 specifications are: Rated current: 2500 A; Poles: 4P; Breaking capacity (Icu): 50 kA; Construction: manual fixed. For anything not listed here, request the Lauritz Knudsen datasheet from VendorStocks at +91 99021 83031 or support@skylightsenergy.in.

Tags

  • UW225NFF01800
  • UW225NFF01800 Lauritz Knudsen
  • ACB U-Power Omega 2500 A - 4 Pole, Manual Fixed, UW-MTX1G Lauritz Knudsen
  • ACB U-Power Omega 2500 A - 4 Pole, Manual Fixed, UW-MTX1G
  • Lauritz Knudsen Air Circuit Breaker
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's warranty policy. See our Terms.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?