MCCB dsine DN1 - 160 A, 4 Pole, 25 kA, Thermal-Magnetic Release

About this product
Lauritz Knudsen dsine DN moulded case circuit breakers with thermal-magnetic release cover 20 A to 630 A in 3 pole and 4 pole versions across the DN0, DN1, DN2, DN3B and DN3 frames at 25 kA, 36 kA, 50 kA and 70 kA breaking capacity. The overload setting is adjustable from 0.8 to 1.0 x In and the short-circuit setting from 6 to 10 x In. Available in manual and rotary versions with a wide range of accessories. Phase barriers are mandatory and are supplied with the MCCB; spreader terminals are recommended for enhanced termination capacity and are ordered separately as accessories unless otherwise specified. Conforms to IS/IEC 60947-2.
Lauritz Knudsen
CM90642OOMOSpecifications
Purchase information
HSN 85362000 · GST 18% · price excludes GST
Product Details
| Field | Value |
|---|---|
| Product Name | MCCB dsine DN1 - 160 A, 4 Pole, 25 kA, Thermal-Magnetic Release |
| Brand | Lauritz Knudsen |
| Catalogue / Part Number | CM90642OOMO |
| SKU | SKYLK858 |
| Product Type | MCCB (Thermal-Magnetic Release) |
| Description | Moulded case circuit breaker, dsine DN1 frame, type designation DN1-250C, 4 Pole, breaking capacity Icu 25 kA at 415 V AC 50 Hz, release setting range 125-160 A. Overload setting adjustable 0.8 - 1.0 x In, short-circuit setting adjustable 6 - 10 x In. For DN0, DN1 and DN3B the short-circuit setting is 9 In. Ics = 100 percent of Icu. Phase barriers supplied with the MCCB. Standard packing 1 no. Catalogue number CM90642OOMO. Conforms to IS/IEC 60947-2. |
| MRP | ₹26,100 |
| Selling Price | ₹26,100 |
| Discount | - |
| GST Rate | 18% |
| HSN Code | 85362000 |
| Currency | INR |
| Availability | In Stock |
| Quantity Available | 5 nos |
| Field | Value |
|---|---|
| Min Order Quantity | 1 nos |
| Location | Bommanahalli |
| Input | 415 V AC 50 Hz |
| Output | - |
| Range | Release setting range 125-160 A |
| Parameters | 4 Pole, dsine DN1 frame, type designation DN1-250C, overload setting adjustable 0.8 - 1.0 x In, short-circuit setting adjustable 6 - 10 x In |
| Supply | - |
| Breaking Capacity | Icu 25 kA at 415 V AC 50 Hz, Ics = 100 percent of Icu |
| Price List Specification | - |
| Weight | 4 kg |
| Volumetric Weight | 1.792 kg |
| Dimensions (L × W × H) | 28 × 20 × 16 cm |
| Datasheet | - |
| Drawing / CAD | - |
The Lauritz Knudsen CM90642OOMO is a 4-pole moulded case circuit breaker rated at 160A with 25kA breaking capacity. It is fitted with a thermal-magnetic release for overload and short-circuit protection and belongs to the dsine DN1 frame. It is used for protection of LT distribution circuits in industrial and commercial installations.
Choose the Lauritz Knudsen CM90642OOMO when your circuit needs 160A protection and the prospective fault current at the point of installation is within 25kA. It gives overload and short-circuit protection in one device. Accessories for remote tripping, status indication and operation differ by frame, so confirm the accessory list for this frame in the Lauritz Knudsen catalogue.
The Lauritz Knudsen CM90642OOMO is used as an incoming or outgoing breaker in main distribution boards (MDBs), sub-distribution boards (SDBs), motor control centers (MCCs), power control centers (PCCs) and feeder circuits, for loads up to 160A.
MCCBs of this type are commonly fitted with a shunt release for remote tripping, an undervoltage release, auxiliary and alarm contacts for status signalling, a motor operator for remote switching, rotary handles for door-mounted operation, extended or spreader terminals, and padlocking devices. Availability depends on the frame size, so check the Lauritz Knudsen accessory list for the CM90642OOMO before ordering.
A thermal magnetic release uses a bimetal for overload and an electromagnet for short-circuit protection. It is simple and cost-effective for standard feeders. An electronic or microprocessor release measures current electronically and offers adjustable overload, short-circuit and, on some versions, earth fault settings. It is preferred where finer coordination between breakers is needed. Lauritz Knudsen names its microprocessor releases MTX on dsine DN breakers and iTRP on dsine DZ breakers.
Calculate the prospective short-circuit current at the point of installation from the transformer kVA and percentage impedance (plus the upstream fault level), reduced by the cable impedance in between, then select an MCCB whose breaking capacity (Icu) at your system voltage (415V) is at least that value. Where supply must continue after a fault, check the service breaking capacity (Ics) too. Breaking capacity versions differ by brand and frame size, so always read the kA value for the exact model. In the Lauritz Knudsen dsine DN and DZ ranges the letter in the type designation shows the Icu at 415V AC: C = 25kA, D = 36kA, N = 50kA, S = 70kA, H = 80kA. Other Lauritz Knudsen MCCB ranges use the letters differently, so always read the kA value stated for the exact model.
Yes, the Lauritz Knudsen CM90642OOMO (MCCB dsine DN1 - 160 A, 4 Pole, 25 kA, Thermal-Magnetic Release) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.
You can buy the Lauritz Knudsen CM90642OOMO online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with product selection.
Yes, VendorStocks takes bulk and project-quantity orders for the Lauritz Knudsen CM90642OOMO. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.
Yes. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your quantity for a formal quotation on the Lauritz Knudsen CM90642OOMO, or add it to your cart and choose “Continue to Buy” to order directly. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.
Yes, you can request the Lauritz Knudsen datasheet for the CM90642OOMO from VendorStocks at +91 99021 83031 or support@skylightsenergy.in.
Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.
Related Products

MCCB dsine DZ2 - 40 A, 3 Pole, 80 kA, Microprocessor Release iTRP3
₹91,500

MCCB dsine DZ1 - 160 A, 3 Pole, 36 kA, Thermal-Magnetic Release
₹31,700

MCCB dsine DZ7 - 800 A, 3 Pole, 80 kA, Microprocessor Release iTRP1
₹1,76,300

MCCB dsine DZ2 - 63 A, 4 Pole, 50 kA, Microprocessor Release iTRP3
₹91,600

MCCB dsine DZ1 - 40 A, 3 Pole, 36 kA, Thermal-Magnetic Release
₹22,200

MCCB dsine DN4 - 1250 A, 3 Pole, 50 kA, Microprocessor Release MTX2.0
₹2,91,900
Related Categories · More from Lauritz Knudsen
Tags
Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.
Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.
Returns, replacements and warranty claims are handled by the seller under the manufacturer's warranty policy. See our Terms.
Your cart is empty
New Account
Create your account to continue
Already have an account?
Welcome back
Sign in to continue
Don't have an account?