MCCB dsine DN2 - 160 A, 4 Pole, 50 kA, Microprocessor Release MTX2.0

CM92157OOOOAG Lauritz Knudsen MCCB dsine DN2 - 160 A, 4 Pole, 50 kA, Microprocessor Release MTX2.0

About this product

Lauritz Knudsen dsine DN moulded case circuit breakers with MTX2.0 microprocessor release cover 40 A to 1250 A in 3 pole and 4 pole versions across the DN2, DN3 and DN4 frames at 36 kA, 50 kA, 70 kA and 100 kA breaking capacity. In addition to the MTX1.0 functions it provides in-built ground fault protection from 20 to 50 percent of In, adjustable neutral overload protection from 50 to 150 percent of Ir, and a panel mounted display for current metering and trip record. Ics equals 100 percent of Icu. Conforms to IS/IEC 60947-2.

CM92157OOOOAG Lauritz Knudsen MCCB dsine DN2 - 160 A, 4 Pole, 50 kA, Microprocessor Release MTX2.0

Lauritz Knudsen

CM92157OOOOAG
₹1,14,900/ nos5 nos in stock
SKYLK990MCCB (Microprocessor Release MTX2.0)1 seller

Specifications

Poles
4
Rated Current
160 A
Breaking Capacity
50 kA
Frame Size
DN2
Protection Type
Microprocessor Release

Purchase information

Availability
In stock — 5 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362000 · GST 18% · price excludes GST

Product Details

FieldValue
Product NameMCCB dsine DN2 - 160 A, 4 Pole, 50 kA, Microprocessor Release MTX2.0
BrandLauritz Knudsen
Catalogue / Part NumberCM92157OOOOAG
SKUSKYLK990
Product TypeMCCB (Microprocessor Release MTX2.0)
DescriptionMoulded case circuit breaker, dsine DN2 frame, type designation DN2-250N, 4 Pole, breaking capacity Icu 50 kA at 415 V AC 50 Hz, release setting range 63-160 A. Overload setting adjustable 0.4 - 1.0 x In, short-circuit setting adjustable 1.5 - 8 x Ir, in-built instantaneous protection, in-built ground fault protection 20 - 50 percent of In, adjustable neutral overload protection 50 - 150 percent of Ir, switchable thermal memory, variable trip class, front LED indication, panel mounted display for current metering and trip record. Ics = 100 percent of Icu. Phase barriers supplied with the MCCB. Standard packing 1 no. Catalogue number CM92157OOOOAG. Conforms to IS/IEC 60947-2.
MRP₹1,14,900
Selling Price₹1,14,900
Discount-
GST Rate18%
HSN Code85362000
CurrencyINR
AvailabilityIn Stock
Quantity Available5 nos
Min Order Quantity1 nos
LocationBommanahalli
Input415 V AC 50 Hz
Output-
RangeRelease setting range 63-160 A
Parameters4 Pole, dsine DN2 frame, type designation DN2-250N, overload setting adjustable 0.4 - 1.0 x In, short-circuit setting adjustable 1.5 - 8 x Ir, in-built instantaneous protection, in-built ground fault protection 20 - 50 percent of In, adjustable neutral overload protection 50 - 150 percent of Ir, switchable thermal memory, variable trip class, front LED indication, panel mounted display for current metering and trip record
Supply-
Breaking CapacityIcu 50 kA at 415 V AC 50 Hz, Ics = 100 percent of Icu
Price List Specification-
Weight4.4 kg
Volumetric Weight2.142 kg
Dimensions (L × W × H)30 × 21 × 17 cm
Datasheet-
Drawing / CAD-

Frequently Asked Questions for Lauritz Knudsen CM92157OOOOAG MCCB

What are the key features of the Lauritz Knudsen CM92157OOOOAG MCCB?

The Lauritz Knudsen CM92157OOOOAG is a 4-pole moulded case circuit breaker rated at 160A with 50kA breaking capacity. It is fitted with a microprocessor MTX2.0 release for overload and short-circuit protection and belongs to the dsine DN2 frame. It is used for protection of LT distribution circuits in industrial and commercial installations.

Why should I choose the Lauritz Knudsen CM92157OOOOAG MCCB?

Choose the Lauritz Knudsen CM92157OOOOAG when your circuit needs 160A protection and the prospective fault current at the point of installation is within 50kA. It gives overload and short-circuit protection in one device. Accessories for remote tripping, status indication and operation differ by frame, so confirm the accessory list for this frame in the Lauritz Knudsen catalogue.

Where is the Lauritz Knudsen CM92157OOOOAG MCCB used in electrical installations?

The Lauritz Knudsen CM92157OOOOAG is used as an incoming or outgoing breaker in main distribution boards (MDBs), sub-distribution boards (SDBs), motor control centers (MCCs), power control centers (PCCs) and feeder circuits, for loads up to 160A.

What accessories can be used with the Lauritz Knudsen CM92157OOOOAG MCCB?

MCCBs of this type are commonly fitted with a shunt release for remote tripping, an undervoltage release, auxiliary and alarm contacts for status signalling, a motor operator for remote switching, rotary handles for door-mounted operation, extended or spreader terminals, and padlocking devices. Availability depends on the frame size, so check the Lauritz Knudsen accessory list for the CM92157OOOOAG before ordering.

What is the difference between thermal magnetic and electronic (microprocessor) releases in MCCBs?

A thermal magnetic release uses a bimetal for overload and an electromagnet for short-circuit protection. It is simple and cost-effective for standard feeders. An electronic or microprocessor release measures current electronically and offers adjustable overload, short-circuit and, on some versions, earth fault settings. It is preferred where finer coordination between breakers is needed. Lauritz Knudsen names its microprocessor releases MTX on dsine DN breakers and iTRP on dsine DZ breakers.

How do I select the right breaking capacity for an MCCB?

Calculate the prospective short-circuit current at the point of installation from the transformer kVA and percentage impedance (plus the upstream fault level), reduced by the cable impedance in between, then select an MCCB whose breaking capacity (Icu) at your system voltage (415V) is at least that value. Where supply must continue after a fault, check the service breaking capacity (Ics) too. Breaking capacity versions differ by brand and frame size, so always read the kA value for the exact model. In the Lauritz Knudsen dsine DN and DZ ranges the letter in the type designation shows the Icu at 415V AC: C = 25kA, D = 36kA, N = 50kA, S = 70kA, H = 80kA. Other Lauritz Knudsen MCCB ranges use the letters differently, so always read the kA value stated for the exact model.

Can I buy Lauritz Knudsen CM92157OOOOAG MCCB through VendorStocks?

Yes, the Lauritz Knudsen CM92157OOOOAG (MCCB dsine DN2 - 160 A, 4 Pole, 50 kA, Microprocessor Release MTX2.0) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.

Where is the best place to buy Lauritz Knudsen CM92157OOOOAG MCCB online in India?

You can buy the Lauritz Knudsen CM92157OOOOAG online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with product selection.

Can I buy Lauritz Knudsen CM92157OOOOAG MCCB in bulk quantity from VendorStocks?

Yes, VendorStocks takes bulk and project-quantity orders for the Lauritz Knudsen CM92157OOOOAG. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.

Can I make an RFQ (Request for Quotation) for Lauritz Knudsen CM92157OOOOAG MCCB?

Yes. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your quantity for a formal quotation on the Lauritz Knudsen CM92157OOOOAG, or add it to your cart and choose “Continue to Buy” to order directly. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.

Can I get the technical datasheet for Lauritz Knudsen CM92157OOOOAG MCCB?

Yes, you can request the Lauritz Knudsen datasheet for the CM92157OOOOAG from VendorStocks at +91 99021 83031 or support@skylightsenergy.in.

What payment methods are accepted on VendorStocks?

Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.

Tags

  • CM92157OOOOAG
  • CM92157OOOOAG Lauritz Knudsen
  • MCCB dsine DN2 - 160 A, 4 Pole, 50 kA, Microprocessor Release MTX2.0 Lauritz Knudsen
  • MCCB dsine DN2 - 160 A, 4 Pole, 50 kA, Microprocessor Release MTX2.0
  • Lauritz Knudsen MCCB
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's warranty policy. See our Terms.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?