MCCB dsine DY125U - 100 A, 3 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release

EM90983OOKO Lauritz Knudsen MCCB dsine DY125U - 100 A, 3 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release

About this product

Lauritz Knudsen dsine DY125U moulded case circuit breakers cover 16 A to 125 A in 2 pole, 3 pole and 4 pole versions with a thermal-magnetic release. Breaking capacity is 10 kA at 415 V AC for 3 pole units and 25 kA at 240 V AC for 2 pole units, with 10 kA at 250 V DC. Ics equals 100 percent of Icu. Features include no load-line bias, ON-TRIP-OFF indication, suitability for isolation, high electrical and mechanical life, and a common sheet steel enclosure for 3P and 4P. Spreader terminals are included and phase barriers are supplied with all MCCBs. Conforms to IS/IEC 60947-2, IEC 60947-2 and EN 60947-2.

EM90983OOKO Lauritz Knudsen MCCB dsine DY125U - 100 A, 3 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release

Lauritz Knudsen

EM90983OOKO
₹3,730/ nos5 nos in stock
SKYLK1112MCCB (Thermal-Magnetic Release)1 seller

Specifications

Operating Voltage
415 V AC
Poles
3
Rated Current
100 A
Breaking Capacity
10 kA
Protection Type
Thermal-Magnetic Release

Purchase information

Availability
In stock — 5 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362000 · GST 18% · price excludes GST

Product Details

FieldValue
Product NameMCCB dsine DY125U - 100 A, 3 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release
BrandLauritz Knudsen
Catalogue / Part NumberEM90983OOKO
SKUSKYLK1112
Product TypeMCCB (Thermal-Magnetic Release)
DescriptionMoulded case circuit breaker, dsine DY125U, 3 Pole, thermal release range 100 A, breaking capacity Icu 10 kA at 415 V AC / 10 kA at 250 V DC. Overload setting adjustable 0.8 - 1.0 x In. Ics = 100 percent of Icu. Phase barriers supplied with the MCCB. Standard packing 1 no. Catalogue number EM90983OOKO. Conforms to IS/IEC 60947-2 and IEC 60947-2.
MRP₹3,730
Selling Price₹3,730
Discount-
GST Rate18%
HSN Code85362000
CurrencyINR
AvailabilityIn Stock
Quantity Available5 nos
Min Order Quantity1 nos
LocationBommanahalli
Input415 V AC / 250 V DC
Output-
RangeThermal release range 100 A
Parameters3 Pole, dsine DY125U, overload setting adjustable 0.8 - 1.0 x In
Supply-
Breaking CapacityIcu 10 kA at 415 V AC / 10 kA at 250 V DC, Ics = 100 percent of Icu
Price List Specification-
Weight1.3 kg
Volumetric Weight0.774 kg
Dimensions (L × W × H)22 × 16 × 11 cm
Datasheet-
Drawing / CAD-

Frequently Asked Questions for Lauritz Knudsen EM90983OOKO MCCB

What are the key features of the Lauritz Knudsen EM90983OOKO MCCB?

The Lauritz Knudsen EM90983OOKO is a 3-pole moulded case circuit breaker rated at 100A with 10kA breaking capacity. It is fitted with a thermal-magnetic release for overload and short-circuit protection. It is used for protection of LT distribution circuits in industrial and commercial installations.

Why should I choose the Lauritz Knudsen EM90983OOKO MCCB?

Choose the Lauritz Knudsen EM90983OOKO when your circuit needs 100A protection and the prospective fault current at the point of installation is within 10kA. It gives overload and short-circuit protection in one device. Accessories for remote tripping, status indication and operation differ by frame, so confirm the accessory list for this frame in the Lauritz Knudsen catalogue.

Where is the Lauritz Knudsen EM90983OOKO MCCB used in electrical installations?

The Lauritz Knudsen EM90983OOKO is used as an incoming or outgoing breaker in main distribution boards (MDBs), sub-distribution boards (SDBs), motor control centers (MCCs), power control centers (PCCs) and feeder circuits, for loads up to 100A.

What accessories can be used with the Lauritz Knudsen EM90983OOKO MCCB?

MCCBs of this type are commonly fitted with a shunt release for remote tripping, an undervoltage release, auxiliary and alarm contacts for status signalling, a motor operator for remote switching, rotary handles for door-mounted operation, extended or spreader terminals, and padlocking devices. Availability depends on the frame size, so check the Lauritz Knudsen accessory list for the EM90983OOKO before ordering.

What is the difference between thermal magnetic and electronic (microprocessor) releases in MCCBs?

A thermal magnetic release uses a bimetal for overload and an electromagnet for short-circuit protection. It is simple and cost-effective for standard feeders. An electronic or microprocessor release measures current electronically and offers adjustable overload, short-circuit and, on some versions, earth fault settings. It is preferred where finer coordination between breakers is needed. Lauritz Knudsen names its microprocessor releases MTX on dsine DN breakers and iTRP on dsine DZ breakers.

How do I select the right breaking capacity for an MCCB?

Calculate the prospective short-circuit current at the point of installation from the transformer kVA and percentage impedance (plus the upstream fault level), reduced by the cable impedance in between, then select an MCCB whose breaking capacity (Icu) at your system voltage (415V) is at least that value. Where supply must continue after a fault, check the service breaking capacity (Ics) too. Breaking capacity versions differ by brand and frame size, so always read the kA value for the exact model.

Can I buy Lauritz Knudsen EM90983OOKO MCCB through VendorStocks?

Yes, the Lauritz Knudsen EM90983OOKO (MCCB dsine DY125U - 100 A, 3 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.

Where is the best place to buy Lauritz Knudsen EM90983OOKO MCCB online in India?

You can buy the Lauritz Knudsen EM90983OOKO online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with product selection.

Can I buy Lauritz Knudsen EM90983OOKO MCCB in bulk quantity from VendorStocks?

Yes, VendorStocks takes bulk and project-quantity orders for the Lauritz Knudsen EM90983OOKO. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.

Can I make an RFQ (Request for Quotation) for Lauritz Knudsen EM90983OOKO MCCB?

Yes. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your quantity for a formal quotation on the Lauritz Knudsen EM90983OOKO, or add it to your cart and choose “Continue to Buy” to order directly. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.

Can I get the technical datasheet for Lauritz Knudsen EM90983OOKO MCCB?

Yes, you can request the Lauritz Knudsen datasheet for the EM90983OOKO from VendorStocks at +91 99021 83031 or support@skylightsenergy.in.

What payment methods are accepted on VendorStocks?

Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.

Tags

  • EM90983OOKO
  • EM90983OOKO Lauritz Knudsen
  • MCCB dsine DY125U - 100 A, 3 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release Lauritz Knudsen
  • MCCB dsine DY125U - 100 A, 3 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release
  • Lauritz Knudsen MCCB
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's warranty policy. See our Terms.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?