Lauritz Knudsen - CM97893OOF2OG - MCCB dsine DN0 - 40 A, 3 Pole, 36 kA, Thermal-Magnetic Release

Lauritz Knudsen - CM97893OOF2OG - MCCB dsine DN0 - 40 A, 3 Pole, 36 kA, Thermal-Magnetic Release

About this product

Lauritz Knudsen dsine DN moulded case circuit breakers with thermal-magnetic release cover 20 A to 630 A in 3 pole and 4 pole versions across the DN0, DN1, DN2, DN3B and DN3 frames at 25 kA, 36 kA, 50 kA and 70 kA breaking capacity. The overload setting is adjustable from 0.8 to 1.0 x In and the short-circuit setting from 6 to 10 x In. Available in manual and rotary versions with a wide range of accessories. Phase barriers are mandatory and are supplied with the MCCB; spreader terminals are recommended for enhanced termination capacity and are ordered separately as accessories unless otherwise specified. Conforms to IS/IEC 60947-2.

Lauritz Knudsen - CM97893OOF2OG - MCCB dsine DN0 - 40 A, 3 Pole, 36 kA, Thermal-Magnetic Release

Catalogue No:

CM97893OOF2OG

Lauritz Knudsen

-50%₹5,800/ nosexcl. GSTM.R.P. ₹11,600₹6,844 incl. 18% GST5 nos in stock
SKYLK827MCCB (Thermal-Magnetic Release)1 seller

Specifications

Poles
3
Rated Current
40 A
Breaking Capacity
36 kA
Frame Size
DN0
Protection Type
Thermal-Magnetic Release

Purchase information

Availability
In stock — 5 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362000 · GST 18% · price includes GST

Product Details

FieldValue
Product NameMCCB dsine DN0 - 40 A, 3 Pole, 36 kA, Thermal-Magnetic Release
BrandLauritz Knudsen
Catalogue / Part NumberCM97893OOF2OG
SKUSKYLK827
Product TypeMCCB (Thermal-Magnetic Release)
MRP (excl. GST)₹11,600
Selling Price (excl. GST)₹5,800
Price incl. GST₹6,844
Discount50% OFF
GST Rate18%
HSN Code85362000
CurrencyINR
AvailabilityIn Stock
Quantity Available5 nos
Min Order Quantity1 nos
LocationBommanahalli
Input415 V AC 50 Hz
Output-
RangeRelease setting range 32-40 A
Supply-
Breaking CapacityIcu 36 kA at 415 V AC 50 Hz, Ics = 50 percent of Icu
Price List Specification-
Key Features
Applications
Technical Specs
ANSI Codes
Protection Functions
Standards Compliance
Weight1.6 kg
Volumetric Weight0.915 kg
Dimensions (L × W × H)22 × 16 × 13 cm
Datasheet-
Drawing / CAD-
Description
Parameters3 Pole, dsine DN0 frame, type designation DN0-100D, overload setting adjustable 0.8 - 1.0 x In, short-circuit setting adjustable 6 - 10 x In

Frequently Asked Questions for Lauritz Knudsen CM97893OOF2OG MCCB

What are the key features of the Lauritz Knudsen CM97893OOF2OG MCCB?

The Lauritz Knudsen CM97893OOF2OG is a 3-pole moulded case circuit breaker rated at 40A with 36kA breaking capacity. It is fitted with a thermal-magnetic release for overload and short-circuit protection and belongs to the dsine DN0 frame. It is used for protection of LT distribution circuits in industrial and commercial installations.

Why should I choose the Lauritz Knudsen CM97893OOF2OG MCCB?

Choose the Lauritz Knudsen CM97893OOF2OG when your circuit needs 40A protection and the prospective fault current at the point of installation is within 36kA. It gives overload and short-circuit protection in one device. Accessories for remote tripping, status indication and operation differ by frame, so confirm the accessory list for this frame in the Lauritz Knudsen catalogue.

Where is the Lauritz Knudsen CM97893OOF2OG MCCB used in electrical installations?

The Lauritz Knudsen CM97893OOF2OG is used as an incoming or outgoing breaker in main distribution boards (MDBs), sub-distribution boards (SDBs), motor control centers (MCCs), power control centers (PCCs) and feeder circuits, for loads up to 40A.

What accessories can be used with the Lauritz Knudsen CM97893OOF2OG MCCB?

MCCBs of this type are commonly fitted with a shunt release for remote tripping, an undervoltage release, auxiliary and alarm contacts for status signalling, a motor operator for remote switching, rotary handles for door-mounted operation, extended or spreader terminals, and padlocking devices. Availability depends on the frame size, so check the Lauritz Knudsen accessory list for the CM97893OOF2OG before ordering.

What is the difference between thermal magnetic and electronic (microprocessor) releases in MCCBs?

A thermal magnetic release uses a bimetal for overload and an electromagnet for short-circuit protection. It is simple and cost-effective for standard feeders. An electronic or microprocessor release measures current electronically and offers adjustable overload, short-circuit and, on some versions, earth fault settings. It is preferred where finer coordination between breakers is needed. Lauritz Knudsen names its microprocessor releases MTX on dsine DN breakers and iTRP on dsine DZ breakers.

How do I select the right breaking capacity for an MCCB?

Calculate the prospective short-circuit current at the point of installation from the transformer kVA and percentage impedance (plus the upstream fault level), reduced by the cable impedance in between, then select an MCCB whose breaking capacity (Icu) at your system voltage (415V) is at least that value. Where supply must continue after a fault, check the service breaking capacity (Ics) too. Breaking capacity versions differ by brand and frame size, so always read the kA value for the exact model. In the Lauritz Knudsen dsine DN and DZ ranges the letter in the type designation shows the Icu at 415V AC: C = 25kA, D = 36kA, N = 50kA, S = 70kA, H = 80kA. Other Lauritz Knudsen MCCB ranges use the letters differently, so always read the kA value stated for the exact model.

Can I buy Lauritz Knudsen CM97893OOF2OG MCCB through VendorStocks?

Yes, the Lauritz Knudsen CM97893OOF2OG (MCCB dsine DN0 - 40 A, 3 Pole, 36 kA, Thermal-Magnetic Release) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.

Tags

  • CM97893OOF2OG
  • CM97893OOF2OG Lauritz Knudsen
  • MCCB dsine DN0 - 40 A, 3 Pole, 36 kA, Thermal-Magnetic Release Lauritz Knudsen
  • MCCB dsine DN0 - 40 A, 3 Pole, 36 kA, Thermal-Magnetic Release
  • Lauritz Knudsen MCCB
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?