Lauritz Knudsen dsine DY125U moulded case circuit breakers cover 16 A to 125 A in 2 pole, 3 pole and 4 pole versions with a thermal-magnetic release. Breaking capacity is 10 kA at 415 V AC for 3 pole units and 25 kA at 240 V AC for 2 pole units, with 10 kA at 250 V DC. Ics equals 100 percent of Icu. Features include no load-line bias, ON-TRIP-OFF indication, suitability for isolation, high electrical and mechanical life, and a common sheet steel enclosure for 3P and 4P. Spreader terminals are included and phase barriers are supplied with all MCCBs. Conforms to IS/IEC 60947-2, IEC 60947-2 and EN 60947-2.

Lauritz Knudsen - EM90984OOKO - MCCB dsine DY125U - 100 A, 4 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release

Catalogue No:

EM90984OOKO

Lauritz Knudsen

-40%₹3,090/ nosexcl. GSTM.R.P. ₹5,150₹3,646.20 incl. 18% GST5 nos in stock
SKYLK1113MCCB (Thermal-Magnetic Release)1 seller

Specifications

Operating Voltage
415 V AC
Poles
4
Rated Current
100 A
Breaking Capacity
10 kA
Protection Type
Thermal-Magnetic Release

Purchase information

Availability
In stock — 5 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362000 · GST 18% · price includes GST

Product Details

FieldValue
BrandLauritz Knudsen
Catalogue / Part NumberEM90984OOKO
SKUSKYLK1113
Product TypeMCCB (Thermal-Magnetic Release)
MRP (excl. GST)₹5,150
Selling Price (excl. GST)₹3,090
Price incl. GST₹3,646.20
Discount40% OFF
GST Rate18%
HSN Code85362000
CurrencyINR
AvailabilityIn Stock
Quantity Available5 nos
Min Order Quantity1 nos
LocationBommanahalli
Input415 V AC / 250 V DC
Output-
RangeThermal release range 100 A
Parameters4 Pole, dsine DY125U, overload setting adjustable 0.8 - 1.0 x In
Supply-
Breaking CapacityIcu 10 kA at 415 V AC / 10 kA at 250 V DC, Ics = 100 percent of Icu
Price List Specification-
Key Features
Applications
Technical Specs
ANSI Codes
Protection Functions
Standards Compliance
Weight1.6 kg
Volumetric Weight0.99 kg
Dimensions (L × W × H)25 × 18 × 11 cm
Datasheet-
Drawing / CAD-
Product NameMCCB dsine DY125U - 100 A, 4 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release
Description

Frequently Asked Questions for Lauritz Knudsen EM90984OOKO MCCB

What are the key features of the Lauritz Knudsen EM90984OOKO MCCB?

The Lauritz Knudsen EM90984OOKO is a 4-pole moulded case circuit breaker rated at 100A with 10kA breaking capacity. It is fitted with a thermal-magnetic release for overload and short-circuit protection. It is used for protection of LT distribution circuits in industrial and commercial installations.

Why should I choose the Lauritz Knudsen EM90984OOKO MCCB?

Choose the Lauritz Knudsen EM90984OOKO when your circuit needs 100A protection and the prospective fault current at the point of installation is within 10kA. It gives overload and short-circuit protection in one device. Accessories for remote tripping, status indication and operation differ by frame, so confirm the accessory list for this frame in the Lauritz Knudsen catalogue.

Where is the Lauritz Knudsen EM90984OOKO MCCB used in electrical installations?

The Lauritz Knudsen EM90984OOKO is used as an incoming or outgoing breaker in main distribution boards (MDBs), sub-distribution boards (SDBs), motor control centers (MCCs), power control centers (PCCs) and feeder circuits, for loads up to 100A.

What accessories can be used with the Lauritz Knudsen EM90984OOKO MCCB?

MCCBs of this type are commonly fitted with a shunt release for remote tripping, an undervoltage release, auxiliary and alarm contacts for status signalling, a motor operator for remote switching, rotary handles for door-mounted operation, extended or spreader terminals, and padlocking devices. Availability depends on the frame size, so check the Lauritz Knudsen accessory list for the EM90984OOKO before ordering.

What is the difference between thermal magnetic and electronic (microprocessor) releases in MCCBs?

A thermal magnetic release uses a bimetal for overload and an electromagnet for short-circuit protection. It is simple and cost-effective for standard feeders. An electronic or microprocessor release measures current electronically and offers adjustable overload, short-circuit and, on some versions, earth fault settings. It is preferred where finer coordination between breakers is needed. Lauritz Knudsen names its microprocessor releases MTX on dsine DN breakers and iTRP on dsine DZ breakers.

How do I select the right breaking capacity for an MCCB?

Calculate the prospective short-circuit current at the point of installation from the transformer kVA and percentage impedance (plus the upstream fault level), reduced by the cable impedance in between, then select an MCCB whose breaking capacity (Icu) at your system voltage (415V) is at least that value. Where supply must continue after a fault, check the service breaking capacity (Ics) too. Breaking capacity versions differ by brand and frame size, so always read the kA value for the exact model.

Can I buy Lauritz Knudsen EM90984OOKO MCCB through VendorStocks?

Yes, the Lauritz Knudsen EM90984OOKO (MCCB dsine DY125U - 100 A, 4 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.

Tags

  • EM90984OOKO
  • EM90984OOKO Lauritz Knudsen
  • MCCB dsine DY125U - 100 A, 4 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release Lauritz Knudsen
  • MCCB dsine DY125U - 100 A, 4 Pole, 10 kA at 415 V AC / 10 kA at 250 V DC, Thermal-Magnetic Release
  • Lauritz Knudsen MCCB
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?