Trinity 5P10 and PS class protection current transformers feed overcurrent, earth fault and differential relays rather than meters. 5P10 units guarantee 5% composite error at 10 times rated current; PS (class X) units are specified by knee-point voltage for differential and restricted earth fault protection. For class 5P20 the price is 1.8 times the 5P10 price. PS class prices are for standard knee-point voltage only, with Rs. 200 extra per additional 5 VA of burden. For ratios below 100/5 A or for better accuracy, a higher ratio CT is selected and the primary conductor is passed through the window several times.

TE-TW-P-150-5VA-PS TRINITY Trinity Tape Wound Protection Current Transformer 150/5A - 5 VA, Class PS

TRINITY

TE-TW-P-150-5VA-PS
₹4,343/ nos5 nos in stock
SKYTR198Current Transformer - Protection (Tape Wound)1 seller

Purchase information

Availability
In stock — 5 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85043100 · GST 18% · price excludes GST

Product Details

FieldValue
Product NameTrinity Tape Wound Protection Current Transformer 150/5A - 5 VA, Class PS
BrandTRINITY
Catalogue / Part NumberTE-TW-P-150-5VA-PS
SKUSKYTR198
Product TypeCurrent Transformer - Protection (Tape Wound)
DescriptionTape Wound protection current transformer, ratio 150/5A, secondary 5 A, burden 5 VA, accuracy class PS, minimum internal diameter 30 mm, maximum outer dimension 125 mm, maximum height 80 mm. For class 5P20 the price is 1.8 times the 5P10 price. PS class price is for standard knee point voltage (Vk) only, with Rs. 200 extra per additional 5 VA. For ratios below 100/5 A or better accuracy, select a higher ratio and pass the primary through the centre (75/5 A: use 300/5 A with 4 turns; 60/5 A: use 300/5 A with 5 turns; 50/5 A: use 250/5 A with 5 turns). Effective 15 January 2026.
MRP₹4,572
Selling Price₹4,343
Discount5% OFF
GST Rate18%
HSN Code85043100
CurrencyINR
AvailabilityIn Stock
Quantity Available5 nos
Min Order Quantity1 nos
LocationBommanahalli
Input-
Output5 A secondary
Range150/5A
ParametersTape Wound protection current transformer, burden 5 VA, accuracy class PS, minimum internal diameter 30 mm, maximum outer dimension 125 mm, maximum height 80 mm
Supply-
Breaking Capacity-
Price List Specification-
Weight2.58 kg
Volumetric Weight0.36 kg
Dimensions (L × W × H)15 × 15 × 8 cm
Datasheet-
Drawing / CAD-

Frequently Asked Questions for TRINITY TE-TW-P-150-5VA-PS Current Transformer

What are the key features of the TRINITY TE-TW-P-150-5VA-PS current transformer?

The TRINITY TE-TW-P-150-5VA-PS is a tape wound protection current transformer with a 150/5A ratio, 5VA burden and Class PS accuracy. It is used for current measurement in protection circuits of LT panels.

Why choose the TRINITY TE-TW-P-150-5VA-PS CT?

Choose the TRINITY TE-TW-P-150-5VA-PS when your feeder needs a 150/5A CT with Class PS accuracy and a connected burden within 5VA. Matching the ratio, class and burden to your relay is what gives correct protection operation.

Where is the TRINITY TE-TW-P-150-5VA-PS CT commonly used?

Class PS CTs are specified by knee-point voltage and feed differential and restricted earth fault protection relays in LT panels.

How do I select the right CT ratio and burden?

Select a primary current just above your maximum load current, for example a 1000/5A CT for an 800A feeder. The CT's VA burden must be higher than the total burden of the meter or relay plus the connecting leads. Use a metering class (such as 0.5 or 1.0) for meters and a protection class (such as 5P10) for relays.

What is the difference between resin cast and tape wound current transformers?

A resin cast CT is encapsulated in epoxy resin, which protects the winding against moisture, dust and mechanical damage. A tape wound CT has its winding insulated with tape and is generally the more economical option for clean, dry indoor panels.

Can I buy TRINITY TE-TW-P-150-5VA-PS current transformer through VendorStocks?

Yes, the TRINITY TE-TW-P-150-5VA-PS (Trinity Tape Wound Protection Current Transformer 150/5A - 5 VA, Class PS) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.

Where is the best place to buy TRINITY current transformers online in India?

You can buy TRINITY current transformers online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with CT selection.

Can I buy TRINITY TE-TW-P-150-5VA-PS current transformer in bulk quantity from VendorStocks?

Yes, VendorStocks takes bulk and project-quantity orders for the TRINITY TE-TW-P-150-5VA-PS. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.

Can I make an RFQ (Request for Quotation) for TRINITY TE-TW-P-150-5VA-PS current transformer?

Yes. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your quantity for a formal quotation on the TRINITY TE-TW-P-150-5VA-PS, or add it to your cart and choose “Continue to Buy” to order directly. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.

Can I get the technical datasheet for TRINITY TE-TW-P-150-5VA-PS current transformer?

Yes, you can request the TRINITY datasheet for the TE-TW-P-150-5VA-PS from VendorStocks at +91 99021 83031 or support@skylightsenergy.in.

What payment methods are accepted on VendorStocks?

Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.

What are the detailed specifications of TRINITY TE-TW-P-150-5VA-PS current transformer?

The TRINITY TE-TW-P-150-5VA-PS specifications are: Ratio: 150/5A; Burden: 5 VA; Accuracy class: PS; Construction: tape wound. For anything not listed here, request the TRINITY datasheet from VendorStocks at +91 99021 83031 or support@skylightsenergy.in.

Tags

  • TE-TW-P-150-5VA-PS
  • TE-TW-P-150-5VA-PS TRINITY
  • Trinity Tape Wound Protection Current Transformer 150/5A - 5 VA, Class PS
  • TRINITY Current Transformer
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's warranty policy. See our Terms.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?