C&S Electric - SR1 - Numeric Automatic Synchronization Relay

📦

About this product

The C&S Electric SR1 is an automatic synchronising relay. Where a check-sync relay only permits or blocks a close decision taken by someone else, an automatic synchroniser does the whole job: it compares the incoming machine with the busbar, drives the governor and AVR until voltage and frequency match, waits for the phase angle to come into the window, and issues the close command with the right lead time.

Documents

Datasheet

C&S Electric - SR1 - Numeric Automatic Synchronization Relay

Catalogue No:

SR1

C&S Electric

₹65,000/ nosexcl. GST₹76,700 incl. 18% GST2 nos in stock
SKYC066Check/Auto Synchronizing Relay1 seller

Purchase information

Availability
In stock — 2 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362010 · GST 18% · price includes GST

Last updated:

Product Details

FieldValue
Product NameNumeric Automatic Synchronization Relay
BrandC&S Electric
Catalogue / Part NumberSR1
SKUSKYC066
Product TypeCheck/Auto Synchronizing Relay
MRP (excl. GST)₹65,000
Selling Price (excl. GST)₹65,000
Price incl. GST₹76,700
Discount-
GST Rate18%
HSN Code85362010
CurrencyINR
AvailabilityIn Stock
Quantity Available2 nos
Min Order Quantity1 nos
LocationBommanahalli
ParametersFor parallel operation of Diesel Generators, Flush Mounting
Breaking CapacityNot published by C&S Electric - confirm contact ratings before ordering
ANSI Codes25A (automatic synchroniser) / 25 (synchronism check)
Weight-
Volumetric Weight-
Dimensions (L × W × H)-
DatasheetView datasheet
Drawing / CAD-
Description
InputBusbar voltage and incoming generator voltage; confirm exact input ratings with C&S Electric
OutputCircuit breaker close command plus raise / lower control outputs to the AVR and governor; confirm contact ratings with C&S Electric
Range
SupplyNot published by C&S Electric - confirm the auxiliary supply option before ordering
Price List Specification
Key Features
Applications
Technical Specs
Protection FunctionsAutomatic matching of generator voltage and frequency to the busbar, followed by circuit-breaker closing when the phase difference is within limits
Standards ComplianceConfirm type-test standards with C&S Electric; no standalone catalogue is published on the C&S website

Frequently Asked Questions for C&S Electric SR1 Check/Auto Synchronizing Relay

What are the key features of the C&S Electric SR1 Check/Auto Synchronizing Relay?

The key features of the C&S Electric SR1 are: Fully automatic synchronising - matches voltage and frequency, then closes the breaker; Raise and lower pulses drive the AVR and the governor directly; Breaker close issued only within a 3 degree phase window; Manual mode gives check-synchronising supervision when an operator parallels by hand; Test mode allows commissioning and routine proving without live equipment.

Where is the C&S Electric SR1 Check/Auto Synchronizing Relay used?

The C&S Electric SR1 is used for: Automatic paralleling of diesel and gas generating sets; Captive power plants synchronising to the grid; Multi-generator installations with automatic load sharing; Standby and emergency generation with automatic changeover; Unmanned generating stations.

What is the C&S Electric SR1 Check/Auto Synchronizing Relay?

The C&S Electric SR1 is the Numeric Automatic Synchronization Relay. Numeric Automatic Synchronization Relay (SR1) from C&S Electric.

What are the technical specifications of the C&S Electric SR1 Check/Auto Synchronizing Relay?

The C&S Electric SR1 technical specifications are: Function: Automatic synchronising relay with Auto, Manual and Test modes; Auto mode: Synchronises generator voltage and frequency within user-set limits and closes the circuit breaker when the phase difference is within 3 degrees; Control outputs: Raise / lower control signals to the generator automatic voltage regulator (AVR) and to the governor; Manual mode: Acts as a check-synchronising permissive only; does not automatically control voltage or frequency; Test mode: Allows the relay to be tested without connecting to live equipment; Phase angle: Breaker close command issued at a phase difference within 3 degrees; Note: Detailed setting ranges for voltage difference, frequency difference, breaker closing time, auxiliary supply, contact ratings and dimensions are not published by C&S; confirm with C&S Electric or Skylights Energy before ordering.

What protection functions does the C&S Electric SR1 Check/Auto Synchronizing Relay provide?

The C&S Electric SR1 provides: Automatic matching of generator voltage and frequency to the busbar, followed by circuit-breaker closing when the phase difference is within limits.

Which ANSI device codes does the C&S Electric SR1 Check/Auto Synchronizing Relay cover?

The C&S Electric SR1 covers ANSI device codes 25A (automatic synchroniser) / 25 (synchronism check).

Which standards does the C&S Electric SR1 Check/Auto Synchronizing Relay comply with?

Standards and compliance for the C&S Electric SR1: Confirm type-test standards with C&S Electric; no standalone catalogue is published on the C&S website.

Tags

  • SR1
  • SR1 C&S Electric
  • Numeric Automatic Synchronization Relay C&S Electric
  • Numeric Automatic Synchronization Relay
  • C&S Electric Check/Auto Synchronizing Relay
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?