C&S Electric - CSE-NEX-I-202 - 3 O/C + 1 E/F Relay with Hi-Set & Autorecloser, 6 DI

About this product
The C&S Electric CSENEX Series are numerical current and voltage protection relays for distribution. They are the workhorse of the C&S range: draw-out construction with self CT shorting, four heavy-duty output relays, auto-reclose, a complete set of IEC inverse curves and Modbus communication, in a 145 x 112 mm cut-out.
Documents
DatasheetC&S Electric
Purchase information
HSN 85362010 · GST 18% · price excludes GST
Last updated:
| Field | Value |
|---|---|
| Product Name | 3 O/C + 1 E/F Relay with Hi-Set & Autorecloser, 6 DI |
| Brand | C&S Electric |
| Catalogue / Part Number | CSE-NEX-I-202 |
| SKU | SKYC025 |
| Product Type | Advance Current Protection Relay |
| MRP (excl. GST) | - |
| Selling Price (excl. GST) | - |
| Price incl. GST | - |
| Discount | - |
| GST Rate | 18% |
| HSN Code | 85362010 |
| Currency | INR |
| Field | Value |
|---|---|
| Availability | In Stock |
| Quantity Available | 2 nos |
| Min Order Quantity | 1 nos |
| Location | Bommanahalli |
| Input | 1A & 5A site selectable |
| Output | 6 DI |
| Parameters | Highset & Autorecloser, Draw-out, CBFP, Front USB & RS 485 |
| Weight | - |
| Volumetric Weight | - |
| Dimensions (L × W × H) | - |
| Datasheet | View datasheet |
| Drawing / CAD | - |
| Description | |
|---|---|
| Range | I> 0.20 to 4.0 x Ip (0.01 step), definite time 0.05-150 s, TMS 0.01-1.50; I>> 0.5 to 30 x Ip, definite time 0.02-20 s |
| Supply | L = 18-60 V DC, H = 85-280 V AC / 110-300 V DC (U = 40-280 V AC / 18-300 V DC on some Hi-Tech models) |
| Breaking Capacity | |
| Price List Specification | |
| Key Features | |
| Applications | |
| Technical Specs | |
| ANSI Codes | 51P/50P, 51N/50N, 37, 27, 59, 59N, 46, 46BC, 47, 50LR, 50S, 49, 50BF, 74TC, 50H, 62CLD, 79, 64R, 50N (model dependent) |
| Protection Functions | |
| Standards Compliance |
The key features of the C&S Electric CSE-NEX-I-202 are: Draw-out case with self CT shorting for safe withdrawal from a live panel; Four digital outputs with a true 8 A continuous carry on relay 1 - enough to drive a trip coil directly; Auto-recloser with four independent dead times and a settable reclaim time; CLOSE and OPEN keys on the front panel for local breaker control; Seven selectable curves including three normal-inverse variants; 10 fault records and 50 event records in non-volatile memory; Modbus RTU on RS-485 at up to 57600 bps with addressing to 247; Wide environmental range from -20 C to +70 C operating.
Choose the C&S Electric CSE-NEX-I-202 when your circuit needs 3 O/C + 1 E/F (phase overcurrent and earth fault) protection. Check the settings range and output contacts in the C&S Electric datasheet against your protection scheme before ordering.
The C&S Electric CSE-NEX-I-202 is used for: MV distribution feeder protection with auto-reclose; Overhead line protection where transient faults are common; Industrial substation incomers and outgoing feeders; Motor and transformer back-up protection (M and U models); Retrofit of electro-mechanical relays on existing distribution switchgear.
Protection relays normally take 1A or 5A CT secondary inputs, and voltage-based functions need a PT secondary input. The exact input rating and burden depend on the model, so confirm them in the C&S Electric CSE-NEX-I-202 datasheet. Use protection class CTs with enough VA burden for the relay and leads.
Electromechanical relays operate with moving parts and offer limited adjustment. Static relays use analog electronics, usually for one protection function. Numerical relays are microprocessor-based, combine several protection functions in one unit, and usually add communication and event recording.
The C&S Electric CSE-NEX-I-202 technical specifications are: Technology: Numerical multi-function protection; draw-out relay with self CT shorting modular design; Rated CT: 1 A / 5 A site selectable; phase and earth rated current programmable 1.00 to 5.00 A; Nominal frequency: 50 / 60 Hz site selectable; Setting - phase: I> 0.20 to 4.0 x Ip (0.01 step), definite time 0.05-150 s, TMS 0.01-1.50; I>> 0.5 to 30 x Ip, definite time 0.02-20 s; Setting - earth: Ie> 0.05 to 2.5 x In (0.01 step), definite time 0.03-150 s, TMS 0.01-1.50; Ie>> 0.5 to 8 x In, definite time 0.02-20 s; Characteristics: DEFT, EINV, VINV, LINV, NINV 1.3, NINV 3.0, NINV 0.6; NPS (46): Pickup 0.10 to 2.5 x Ip; DEFT or NPS-INV; time multiplier K1 5.0-600; definite time 0.10-600 s; CBFP / TCS: 0.05 to 2 s (5 s on the 203 model); Broken conductor: NPS/PPS ratio 0.10-0.50; definite trip time 0.05-20 s; Auto-recloser: Dead times D1-D4 and reclaim time 0.20-300 s; 2 to 4 AR cycles per protection; trip sense time 0.05-2 s; CT ratio: 1 to 7000 (phase and earth); Accuracy: Current +2% over 1 to 30 x Ip; voltage +2% over 5-40 V; pickup +5% of setting (current), +6% (voltage); drop-out to pickup > 96%; Trip timing accuracy: DEFT, NINV 0.6/1.3/3.0: +5% or +30 ms; EINV, VINV, LINV: +7.5% or +40 ms; Thermal withstand: 250 x Ip half wave; 100 x Ip for 1 s; 30 x Ip for 10 s; 4 x Ip continuous; CT burden: 0.2 VA at 1 A; 0.4 VA at 5 A; Auxiliary supply: L = 18-60 V DC, H = 85-280 V AC / 110-300 V DC (U = 40-280 V AC / 18-300 V DC on some Hi-Tech models); Power consumption: Approx. 3 W quiescent; < 7 W operating; Digital outputs: 4 relay outputs - DO1 and DO2 change-over, DO3 and DO4 normally open; carry 8 A (relay 1) and 4 A (relays 2-4); make 30 A for 3 s; 250 V AC / 30 V DC; breaking 1500 VA resistive; operate time < 10 ms; 10,000 loaded / 30,000 unloaded operations; Records: 10 fault records and 50 event records in non-volatile memory with date and time stamp; Communication: Front USB type A with CSE LIVELINK at 19200 bps; rear RS-485 Modbus RTU, 4800-57600 bps, address 1-247; Display: 16 x 4 alphanumeric LCD, 8 pickup/trip LEDs plus 3 function LEDs; RESET, F1, CLOSE and OPEN keys; Case: 125 x 154 x 156 mm (W x H x D); panel cut-out 145 x 112 mm; weight approx. 1.0 kg; IP 54 front, IP 00 rear; Environment: Operating -20 to +70 C; storage -40 to +85 C; humidity 95% at 40 C for 56 days; Ordering code: CSENEX-I-(201/202/203)-(L/H).
The C&S Electric CSE-NEX-I-202 provides: Multi-function current and voltage protection for distribution: IDMTL and instantaneous over current and earth fault, under current, under and over voltage, neutral displacement, current unbalance / NPS, broken conductor, locked rotor, stall, thermal overload, latch relay, breaker failure, trip circuit supervision, harmonic blocking, cold load pickup, auto-recloser and restricted earth fault, by model.
The C&S Electric CSE-NEX-I-202 covers ANSI device codes 51P/50P, 51N/50N, 37, 27, 59, 59N, 46, 46BC, 47, 50LR, 50S, 49, 50BF, 74TC, 50H, 62CLD, 79, 64R, 50N (model dependent).
Standards and compliance for the C&S Electric CSE-NEX-I-202: VDE 0435 part 303, IEC 60255-4 / BS 142 (inverse curves), IEC 60255-5 (2.5 kV 1 min, 5 kV 1.2/50 us impulse), 2.5 kV/1 MHz HF, 4 kV/2.5 kHz fast transient, 8 kV ESD, 10 V/m radiated field, radio interference class B.
Yes, the C&S Electric CSE-NEX-I-202 (3 O/C + 1 E/F Relay with Hi-Set & Autorecloser, 6 DI) is listed on VendorStocks. Add it to your cart and choose “Request RFQ”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.
You can buy C&S Electric protection relays online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with relay selection.
Yes, VendorStocks takes bulk and project-quantity orders for the C&S Electric CSE-NEX-I-202. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.
Yes. Add the C&S Electric CSE-NEX-I-202 to your cart and choose “Request RFQ”, and the seller replies with a quotation. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.
Yes, the C&S Electric datasheet for the CSE-NEX-I-202 can be downloaded from the Documents section of this product page.
Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.

C&S Electric - MRF2 - Numeric Multistage Frequency Relay
₹70,000excl. GST₹82,600 incl. 18% GST

C&S Electric - CSEZen-F550x - Advance Multifunction Feeder Protection Relay F550x
RFQ

C&S Electric - IRI-ProX-EOR - Restricted Earth Fault Relay
₹12,500excl. GST₹14,750 incl. 18% GST

C&S Electric - IRI-PROX-3R-V5-WITH-RES - Restricted Earth Fault Relay V5 with Resistor
RFQ

C&S Electric - CSENEX-I150 - Numerical Multifunction Feeder Relay NEX-I150
₹22,500excl. GST₹26,550 incl. 18% GST

C&S Electric - IRU-Pro-UOR - Numeric Under/Over Voltage & Neutral Displacement Relay
₹23,000excl. GST₹27,140 incl. 18% GST
Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.
Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.
Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.
Your cart is empty
New Account
Create your account to continue
Already have an account?
Welcome back
Sign in to continue
Don't have an account?