C&S Electric - IRD1-T2-WG - Numeric Transformer Differential Relay

C&S Electric - IRD1-T2-WG - Numeric Transformer Differential Relay

About this product

The C&S Electric IRD1-T2 is a numerical transformer differential relay providing fast, unit protection for two-winding transformers. Differential protection compares the current entering a transformer with the current leaving it. In theory any difference means an internal fault; in practice CT ratio mismatch, tap changer position, vector-group phase shift and CT saturation all produce a difference, and transformer magnetising inrush at energisation produces a very large one. The IRD1-T2 is built to distinguish those from a real fault.

Documents

Datasheet

C&S Electric - IRD1-T2-WG - Numeric Transformer Differential Relay

Catalogue No:

IRD1-T2-WG

C&S Electric

₹55,000/ nosexcl. GST₹64,900 incl. 18% GST2 nos in stock
SKYC072Transformer Protection Relay1 seller

Purchase information

Availability
In stock — 2 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362010 · GST 18% · price includes GST

Last updated:

Product Details

FieldValue
Product NameNumeric Transformer Differential Relay
BrandC&S Electric
Catalogue / Part NumberIRD1-T2-WG
SKUSKYC072
Product TypeTransformer Protection Relay
MRP (excl. GST)₹55,000
Selling Price (excl. GST)₹55,000
Price incl. GST₹64,900
Discount-
GST Rate18%
HSN Code85362010
CurrencyINR
AvailabilityIn Stock
Quantity Available2 nos
Min Order Quantity1 nos
LocationBommanahalli
Input1 A or 5 A
OutputTwo trip relays, each with two change-over contacts (four in total)
RangeA fixed Id1 = Id2 = 60% applies when harmonics are present
Supply
  • L: 18-60 V DC
  • H: 85-280 V AC / 90-300 V DC
ANSI Codes87T (transformer differential) / 87G (generator differential)
Standards ComplianceIEC 60255 series; confirm full type-test schedule with C&S Electric
Weight-
Volumetric Weight-
Dimensions (L × W × H)-
DatasheetView datasheet
Drawing / CAD-
Description
ParametersInstantaneous differential, programmable vector group, programmable 2nd and 5th harmonic threshold, front RS 232 and Rear RS 485 communication, Flush Drawout
Breaking CapacityTwo trip relays, each with two change-over contacts (four in total); confirm contact ratings with C&S Electric
Price List Specification
Key Features
Applications
Technical Specs
Protection Functions

Frequently Asked Questions for C&S Electric IRD1-T2-WG Protection Relay

What are the key features of the C&S Electric IRD1-T2-WG relay?

The key features of the C&S Electric IRD1-T2-WG are: Dual-slope bias characteristic gives sensitivity for internal faults and stability for CT errors on through faults; Internal CT ratio correction from 30% to 150% removes the need for external interposing CTs; Second-harmonic restraint blocks tripping on magnetising inrush at energisation; Fifth-harmonic restraint prevents tripping on transformer over-excitation; Unrestrained high-set stage trips instantly on a heavy internal fault; Dedicated inrush and harmonic-block LEDs show exactly why the relay restrained; Generator variant (G2) available for YY0 machine differential duty.

Why choose the C&S Electric IRD1-T2-WG relay?

Choose the C&S Electric IRD1-T2-WG when your transformer circuit needs transformer differential protection. Check the settings range and output contacts in the C&S Electric datasheet against your protection scheme before ordering.

Where is the C&S Electric IRD1-T2-WG relay used?

The C&S Electric IRD1-T2-WG is used for: Two-winding power and distribution transformer protection; Generator differential protection (IRD1-G2); Unit transformer and auxiliary transformer protection; Industrial substation transformers from distribution to power rating; Retrofit replacement of electro-mechanical biased differential relays.

What CT and PT inputs are needed for the C&S Electric IRD1-T2-WG relay?

Protection relays normally take 1A or 5A CT secondary inputs, and voltage-based functions need a PT secondary input. The exact input rating and burden depend on the model, so confirm them in the C&S Electric IRD1-T2-WG datasheet. Use protection class CTs with enough VA burden for the relay and leads.

What is the difference between numerical, static and electromechanical protection relays?

Electromechanical relays operate with moving parts and offer limited adjustment. Static relays use analog electronics, usually for one protection function. Numerical relays are microprocessor-based, combine several protection functions in one unit, and usually add communication and event recording.

What are the technical specifications of the C&S Electric IRD1-T2-WG relay?

The C&S Electric IRD1-T2-WG technical specifications are: Models: IRD1-T2 two-winding transformer differential; IRD1-G2 generator differential, fixed YY0 vector group without harmonic blocking; Characteristic: Dual slope - Id1 as a fraction of In (basic pickup / bias) and Id2 as a fraction of Is (slope), plus a high-set threshold; CT ratio correction: 30% to 150% of In on both primary and secondary sides; Harmonic restraint: 2nd and 5th harmonic inrush stabilisation; HBLOCK settable, 20% suggested where no harmonic data is available; Coarse setting: A fixed Id1 = Id2 = 60% applies when harmonics are present; Rated current: 1 A or 5 A; Current inputs: HV side on terminals A3 to A8; LV side on terminals B3 to B8; Auxiliary supply: L: 18-60 V DC; H: 85-280 V AC / 90-300 V DC; Power consumption: Approx. 3 W quiescent; < 7 W operating; Output relays: Two trip relays, each with two change-over contacts (four in total); Front indication: 8 LEDs - ON, L1, L2, L3, TRIP, harmonic block, inrush and COMM; Communication: Front RS-232 port; rear RS-485; serial interface terminals N, P and G; Fault records: Last three faults stored in EPROM, Fault 1 being the most recent; Panel cut-out: 139.0 x 70.0 mm; general tolerance +/- 1.0 mm; keep 50 mm clearance between units mounted one below another; Ordering code: IRD1-(T2/G2)-(1/5)-(L/H).

What protection functions does the C&S Electric IRD1-T2-WG relay provide?

The C&S Electric IRD1-T2-WG provides: Two-winding transformer differential protection with dual-slope bias characteristic, 2nd and 5th harmonic inrush restraint and an unrestrained high-set stage; generator differential on the G2 variant.

Tags

  • IRD1-T2-WG
  • IRD1-T2-WG C&S Electric
  • Numeric Transformer Differential Relay C&S Electric
  • Numeric Transformer Differential Relay
  • C&S Electric Protection Relay
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?