C&S Electric - CSFPI-V3-SC - Fault Passage Indicator for Short Circuit & Earth Fault

C&S Electric - CSFPI-V3-SC - Fault Passage Indicator for Short Circuit & Earth Fault

About this product

The C&S Electric CSFPI Fault Passage Indicator detects and indicates earth faults and short circuits on cable systems in RMU networks with a one-input or open-ring arrangement. In an underground MV ring, a cable fault gives no visible sign. Without fault passage indicators a crew has to section and test the ring manually, which can take hours. With them, each RMU shows at a glance whether fault current passed through it, and the faulted section is identified in minutes.

Documents

Datasheet

C&S Electric - CSFPI-V3-SC - Fault Passage Indicator for Short Circuit & Earth Fault

Catalogue No:

CSFPI-V3-SC

C&S Electric

Request for Quote (RFQ)2 nos in stock
SKYC022Self Powered Relay - RMU1 seller

Purchase information

Availability
In stock — 2 nos ready to ship
Minimum order
1 nos
Ships from
Bommanahalli · 560068
Delivery
Across India · shipping calculated at checkout from your pincode
  • 100% Genuine
  • Manufacturer Warranty
  • Secure Payments
  • Delivery Across India

HSN 85362010 · GST 18% · price excludes GST

Last updated:

Product Details

FieldValue
Product NameFault Passage Indicator for Short Circuit & Earth Fault
BrandC&S Electric
Catalogue / Part NumberCSFPI-V3-SC
SKUSKYC022
Product TypeSelf Powered Relay - RMU
MRP (excl. GST)-
Selling Price (excl. GST)-
Price incl. GST-
Discount-
GST Rate18%
HSN Code85362010
CurrencyINR
AvailabilityIn Stock
Quantity Available2 nos
Min Order Quantity1 nos
LocationBommanahalli
Range100 / 200 / 300 / 400 / 500 / 600 / 700 / 800 / 900 / 1000 / 1100 / 1200 A
ParametersFor Short circuit and Earthfault, Different output combinations
ANSI CodesFault passage indication - no protection ANSI code (designed per IEEE 495-2007)
Weight-
Volumetric Weight-
Dimensions (L × W × H)-
DatasheetView datasheet
Drawing / CAD-
Description
InputCable-mounted phase sensor and earth sensor on screened MV cable; retrofittable without breaking the circuit
OutputUp to three potential free contacts for earth fault, short circuit and battery low remote indication
SupplyInternal lithium thionyl-chloride industrial grade long life battery with battery check facility; no external supply required for indication
Breaking CapacityUp to three potential free contacts for earth fault, short circuit and battery low remote indication
Price List Specification
Key Features
Applications
Technical Specs
Protection FunctionsDetection and indication of earth fault and short circuit on a cable system in RMU networks with one input / open ring arrangement
Standards ComplianceDesigned as per IEEE 495-2007; 20 kA short circuit withstand capability as per breaker rating

Frequently Asked Questions for C&S Electric CSFPI-V3-SC Self Powered Relay - RMU

What are the key features of the C&S Electric CSFPI-V3-SC Self Powered Relay - RMU?

The key features of the C&S Electric CSFPI-V3-SC are: Programmable short circuit pickup over a wide 100 A to 1200 A range; Programmable earth fault pickup from 10 A to 100 A; Independently programmable response delay for short circuits and earth faults; Long-life lithium thionyl-chloride battery with a built-in battery check facility; Retrofittable cable-mounted sensors - no need to break the cable; Four reset options including automatic reset by time current recovery; SCADA ready over RS-485 Modbus with three potential free contacts.

Where is the C&S Electric CSFPI-V3-SC Self Powered Relay - RMU used?

The C&S Electric CSFPI-V3-SC is used for: Locating faults in MV ring main and open-ring cable networks; Reducing outage time by showing crews which section carried the fault current; Retrofit on existing screened MV cables in RMUs and compact substations; Utility distribution networks with remote SCADA fault location; Underground cable networks where visual fault location is impossible.

What is the C&S Electric CSFPI-V3-SC Self Powered Relay - RMU?

The C&S Electric CSFPI-V3-SC is the Fault Passage Indicator for Short Circuit & Earth Fault. Fault Passage Indicator for Short Circuit & Earth Fault (CSFPI-V3-SC) from C&S Electric.

What are the technical specifications of the C&S Electric CSFPI-V3-SC Self Powered Relay - RMU?

The C&S Electric CSFPI-V3-SC technical specifications are: Function: Indicates a fault condition when current is detected above the set trip current; fault current is sensed by a cable-mounted sensor which signals the indication unit; Sensors: Cable-mounted phase sensor and earth sensor; must be mounted on screened cables and can be retrofitted; Short circuit trip current: 100 / 200 / 300 / 400 / 500 / 600 / 700 / 800 / 900 / 1000 / 1100 / 1200 A; Earth fault trip current: 10 / 20 / 30 / 40 / 60 / 80 / 100 A; Short circuit response time: 40 / 60 / 80 / 100 / 120 / 160 / 200 / 240 ms (C1 variant: up to 500 ms); Earth fault response time: 40 / 60 / 80 / 160 ms (C1 variant: 40 / 80 / 200 / 500 ms); Battery: Lithium thionyl-chloride industrial grade long life battery, with battery check facility; Indication: Blinking short-circuit LEDs for a short circuit; blinking earth-fault LED for a permanent earth fault; Output contacts: Up to three potential free contacts for earth fault, short circuit and battery low remote indication; Reset options: Manually by push button, remote potential free input, by time current recovery, or AC/DC voltage; Communication: SCADA compatibility with RS-485 port on MODBUS protocol; Dimensions: 51.75 (H) x 97.75 (W) x 92.0 (D) mm; Mounting: Suitable for panel installation.

What protection functions does the C&S Electric CSFPI-V3-SC Self Powered Relay - RMU provide?

The C&S Electric CSFPI-V3-SC provides: Detection and indication of earth fault and short circuit on a cable system in RMU networks with one input / open ring arrangement.

Which ANSI device codes does the C&S Electric CSFPI-V3-SC Self Powered Relay - RMU cover?

The C&S Electric CSFPI-V3-SC covers ANSI device codes Fault passage indication - no protection ANSI code (designed per IEEE 495-2007).

Which standards does the C&S Electric CSFPI-V3-SC Self Powered Relay - RMU comply with?

Standards and compliance for the C&S Electric CSFPI-V3-SC: Designed as per IEEE 495-2007; 20 kA short circuit withstand capability as per breaker rating.

Tags

  • CSFPI-V3-SC
  • CSFPI-V3-SC C&S Electric
  • Fault Passage Indicator for Short Circuit & Earth Fault C&S Electric
  • Fault Passage Indicator for Short Circuit & Earth Fault
  • C&S Electric Self Powered Relay - RMU
  • VendorStocks India

Payment, Delivery & Returns

Secure payments

Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.

Delivery

Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.

Returns & warranty

Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.

Cart

Your cart is empty

New Account

Create your account to continue

or

Already have an account?

Welcome back

Sign in to continue

or

Don't have an account?