C&S Electric - MRI1-IR-SR - Directional Relay for Solid Earthed System

About this product
The C&S Electric MRI1 is a numerical directional overcurrent and earth-fault relay from the High-Tech MR range. On a radial feeder, plain overcurrent grading is enough. On a ring, a parallel feeder or a meshed network, fault current can arrive from either end, and a non-directional relay will trip the healthy circuit as readily as the faulted one. The MRI1 adds a direction decision to the current measurement so that only the relay looking into the fault operates.
Documents
DatasheetC&S Electric
Purchase information
HSN 85362010 · GST 18% · price includes GST
Last updated:
| Field | Value |
|---|---|
| Product Name | Directional Relay for Solid Earthed System |
| Brand | C&S Electric |
| Catalogue / Part Number | MRI1-IR-SR |
| SKU | SKYC007 |
| Product Type | Basic Current Protection Relay |
| MRP (excl. GST) | ₹49,500 |
| Selling Price (excl. GST) | ₹49,500 |
| Price incl. GST | ₹58,410 |
| Discount | - |
| GST Rate | 18% |
| HSN Code | 85362010 |
| Currency | INR |
| Availability | In Stock |
| Field | Value |
|---|---|
| Quantity Available | 2 nos |
| Min Order Quantity | 1 nos |
| Location | Bommanahalli |
| Input | 1A/5A |
| Output | Up to 5 (trip 2 change-over; alarms 1 change-over each) |
| ANSI Codes | 50, 51, 50N, 51N, 67, 67N, 50BF |
| Standards Compliance | IEC 60255-4 / BS 142 inverse characteristics; GL and Bureau Veritas approved |
| Weight | - |
| Volumetric Weight | - |
| Dimensions (L × W × H) | - |
| Datasheet | View datasheet |
| Drawing / CAD | - |
| Description | |
|---|---|
| Range | I> 0.2-4.0 x In; I>> 1-40 x In; tI> 0.03-260 s definite time; IE> 0.01-2.0 x In; IE>> 0.01-15 x In; CBFP 0.1-2 s |
| Parameters | Highset, for solidly earthed system, rear RS 485 communication, display with keypad |
| Supply |
|
| Breaking Capacity | 250 x In dynamic; 100 x In for 1 s; 30 x In for 10 s; 4 x In continuous; VT 1.5 x UN continuous |
| Price List Specification | |
| Key Features | |
| Applications | |
| Technical Specs | |
| Protection Functions |
The key features of the C&S Electric MRI1-IR-SR are: Phase and earth directional decision with selectable relay characteristic angle in seven steps; Earth-fault direction configurable for solid, resistance earthed, isolated or compensated systems; Withdrawable modules with automatic CT short-circuiting - safe removal under load; Transient overreach below 5% and dropout ratio above 97%; Inverse curves to IEC 255-4 / BS 142 plus definite time; Germanischer Lloyd and Bureau Veritas approved for marine use.
The C&S Electric MRI1-IR-SR is the Directional Relay for Solid Earthed System. Directional Relay for Solid Earthed System (MRI1-IR-SR) from C&S Electric.
The C&S Electric MRI1-IR-SR is used for: MV feeder protection on doubly-fed lines and meshed systems; Back-up protection for distance and differential schemes; Ring main and parallel-feeder discrimination; Industrial and utility distribution substations; Marine and offshore power systems.
Protection relays normally take 1A or 5A CT secondary inputs, and voltage-based functions need a PT secondary input. The exact input rating and burden depend on the model, so confirm them in the C&S Electric MRI1-IR-SR datasheet. Use protection class CTs with enough VA burden for the relay and leads.
Electromechanical relays operate with moving parts and offer limited adjustment. Static relays use analog electronics, usually for one protection function. Numerical relays are microprocessor-based, combine several protection functions in one unit, and usually add communication and event recording.
The C&S Electric MRI1-IR-SR technical specifications are: Technology: Microprocessor-based numerical relay with front display, digital (Fourier) filtering and self-supervision watchdog output relay; Auxiliary supply: Code L: 24 V (16-60 V AC / 16-80 V DC); Code H: 110 V (50-270 V AC / 70-360 V DC); Communication: RS485 serial interface, optional (order code R); slave address 1-32; Housing: 12TE; code A = 19 inch rack, code D = flush mounting; Inputs / outputs: Blocking input (aux voltage on D8/E8); electrical reset input (aux voltage on C8/D8); Installation: Installation depth 275 mm; leave 50 mm between units mounted one above another as the front cover opens downwards; Measuring inputs: 3 x CT 1 A / 5 A plus earth CT; VT 100 / 230 / 400 V; Rated frequency: 50 / 60 Hz adjustable; Setting ranges: I> 0.2-4.0 x In; I>> 1-40 x In; tI> 0.03-260 s definite time; IE> 0.01-2.0 x In; IE>> 0.01-15 x In; CBFP 0.1-2 s; Characteristics: Definite time or inverse time - Normal, Very and Extremely Inverse per IEC 255-4 / BS 142; Directional: Phase RCA 15/27/38/49/61/72/83 degrees in 7 steps. Earth: SR 110 deg / 170 deg for solid or resistance earthed systems, or ER for isolated / compensated systems; Output relays: Up to 5 (trip 2 change-over; alarms 1 change-over each); Burden: CT 0.2 VA at 1 A / 0.1 VA at 5 A; VT < 1 VA; Thermal rating: 250 x In dynamic; 100 x In for 1 s; 30 x In for 10 s; 4 x In continuous; VT 1.5 x UN continuous; Timing: Returning time 30 ms; minimum operating time 30 ms; time lag error +/- 10 ms; Other: Dropout ratio > 97%; transient overreach < 5%; Mechanical: Withdrawable modules with automatic CT short-circuiting; Ordering code: MRI1-(phase)(earth)-(aux)(RS485)(housing).
The C&S Electric MRI1-IR-SR provides: Directional and non-directional phase overcurrent (I>, I>>), directional and non-directional earth fault (IE>, IE>>), phase and earth directional decision, circuit breaker failure protection.
The C&S Electric MRI1-IR-SR covers ANSI device codes 50, 51, 50N, 51N, 67, 67N, 50BF.
Standards and compliance for the C&S Electric MRI1-IR-SR: IEC 60255-4 / BS 142 inverse characteristics; GL and Bureau Veritas approved.
Yes, the C&S Electric MRI1-IR-SR (Directional Relay for Solid Earthed System) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.
You can buy C&S Electric protection relays online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with relay selection.
Yes, VendorStocks takes bulk and project-quantity orders for the C&S Electric MRI1-IR-SR. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.
Yes. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your quantity for a formal quotation on the C&S Electric MRI1-IR-SR, or add it to your cart and choose “Continue to Buy” to order directly. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.
Yes, the C&S Electric datasheet for the MRI1-IR-SR can be downloaded from the Documents section of this product page.
Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.
C&S Electric - IRIPROX-3ER-V-5 - Static High Impedance Differential Relay V5
RFQ
C&S Electric - IRI-PRO-V2-EO-1 - Earth Fault Relay V2 (1A)
RFQ

C&S Electric - IRI-PRO-V2-3I-EI-1-1 - 3 O/C + 1 E/F Relay V2 (1A, 1 Output)
RFQ

C&S Electric - IRD1-T2-WG - Numeric Transformer Differential Relay
₹55,000excl. GST₹64,900 incl. 18% GST

C&S Electric - MRI1-IE - Non-Directional 3 O/C + E/F Relay
₹39,050excl. GST₹46,079 incl. 18% GST

C&S Electric - BU1-AC-O - 3 Phase Over Voltage Relay
₹9,000excl. GST₹10,620 incl. 18% GST
Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.
Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.