C&S Electric - MRR1 - Numeric Rotor Earthfault Protection Relay

About this product
The C&S Electric MRR1 is a multifunctional generator rotor protection relay combining rotor earth-fault protection, excitation over- and under-current protection and rotating diode failure detection. A single earth fault on a field winding does no immediate damage - which is precisely why it must be found. A second earth fault would short part of the field winding, unbalance the magnetic flux and cause severe mechanical damage to the machine.
Documents
DatasheetC&S Electric
Purchase information
HSN 85362010 · GST 18% · price includes GST
Last updated:
| Field | Value |
|---|---|
| Product Name | Numeric Rotor Earthfault Protection Relay |
| Brand | C&S Electric |
| Catalogue / Part Number | MRR1 |
| SKU | SKYC064 |
| Product Type | Generator & Power Protection Relay |
| MRP (excl. GST) | ₹1,85,000 |
| Selling Price (excl. GST) | ₹1,85,000 |
| Price incl. GST | ₹2,18,300 |
| Discount | - |
| GST Rate | 18% |
| HSN Code | 85362010 |
| Currency | INR |
| Field | Value |
|---|---|
| Availability | In Stock |
| Quantity Available | 2 nos |
| Min Order Quantity | 1 nos |
| Location | Bommanahalli |
| Input | 1 kOhm to 1 MOhm |
| Standards Compliance | IEC 60255 series |
| Weight | - |
| Volumetric Weight | - |
| Dimensions (L × W × H) | - |
| Datasheet | View datasheet |
| Drawing / CAD | - |
| Description | |
|---|---|
| Output | 5 (R1-R2 with 2 change-over; R3-R4 with 1 change-over; R5 self-supervision, normally energised) |
| Range | RW 20-200 kOhm; R< 2-20 kOhm; tRW and tR< 1-50 s; Ie< and Ie> 0.2-20 A; tIe 0.1-10 s; Ir 10-400% |
| Parameters | Diode failure and under/over excitation protection for large Generators with RS 485 communication, Flush Mounting, Drawout |
| Supply |
|
| Breaking Capacity | 5 output relays - R1 and R2 with 2 change-over contacts each, R3 and R4 with 1 change-over each, R5 self-supervision normally energised |
| Price List Specification | |
| Key Features | |
| Applications | |
| Technical Specs | |
| ANSI Codes | 37 (DC undercurrent), 40 (field relay), 58 (rectification failure), 64 (ground detector), 76 (DC overcurrent) |
| Protection Functions | Two-stage rotor earth fault (warning RW and trip R<), exciter DC undercurrent (Ie<), exciter DC overcurrent (Ie>) and rotating diode failure by ripple detection (Ir) |
The key features of the C&S Electric MRR1 are: Detects high-impedance rotor earth faults using a 0.5 Hz test voltage, which avoids false measurement from rotor-to-earth capacitance up to 1 uF; Two-stage insulation supervision - one stage for warning, one for trip, with independent resistance and time settings; Live display of insulation resistance in kOhm and exciter current in amps; Rotating diode failure detection by measuring the ripple component of the excitation current; Hall-transducer current measurement, galvanically isolated, 0 to 20 A range; Short-circuit and overvoltage proof measuring input; Programmable blocking input and assignment of functions to output relays as alarm or trip.
Choose the C&S Electric MRR1 when your generator circuit needs earth fault protection. Check the settings range and output contacts in the C&S Electric datasheet against your protection scheme before ordering.
The C&S Electric MRR1 is used for: Rotor earth-fault protection of synchronous generators, brushed and brushless; Excitation system supervision on turbo and hydro generators; Rotating diode failure detection on brushless exciters; Field failure and over-excitation protection; Power station and captive generation protection panels.
Protection relays normally take 1A or 5A CT secondary inputs, and voltage-based functions need a PT secondary input. The exact input rating and burden depend on the model, so confirm them in the C&S Electric MRR1 datasheet. Use protection class CTs with enough VA burden for the relay and leads.
Electromechanical relays operate with moving parts and offer limited adjustment. Static relays use analog electronics, usually for one protection function. Numerical relays are microprocessor-based, combine several protection functions in one unit, and usually add communication and event recording.
The C&S Electric MRR1 technical specifications are: Technology: Microprocessor-based numerical relay with front display, digital (Fourier) filtering and self-supervision watchdog output relay; Auxiliary supply: Code L: 24 V (16-60 V AC / 16-80 V DC); Code H: 110 V (50-270 V AC / 70-360 V DC); Communication: RS485 serial interface, optional (order code R); slave address 1-32; Housing: 12TE; code A = 19 inch rack, code D = flush mounting; Inputs / outputs: Blocking input (aux voltage on D8/E8); electrical reset input (aux voltage on C8/D8); Installation: Installation depth 275 mm; leave 50 mm between units mounted one above another as the front cover opens downwards; Insulation measurement: Low frequency alternating test voltage +/- 24 V at 0.5 Hz injected via slip rings to the main exciter winding and rotor earth; Measuring resistance range: 1 kOhm to 1 MOhm; Max input voltage: 600 V DC; Exciter DC current measurement: Galvanically isolated via Hall transducer; nominal current IN 10 A DC; measuring range 0 to 20 A; Power consumption in current circuit: < 1 VA; Setting ranges: RW 20-200 kOhm; R< 2-20 kOhm; tRW and tR< 1-50 s; Ie< and Ie> 0.2-20 A; tIe 0.1-10 s; Ir 10-400%; Default settings: RW 80.0 kOhm, tRW 1.00 s; R< 20.0 kOhm, tR< 1.00 s; Ie< 0.50 A, tIe< 0.10 s; Ie> 5.00 A, tIe> 0.1 s; Ir 50%, tIr 0.1 s; Accuracy: Insulation and current pickup +/- 5% of setting; trip delays +/- 3% or +/- 150 ms; Output relays: 5 (R1-R2 with 2 change-over; R3-R4 with 1 change-over; R5 self-supervision, normally energised); Timing: Returning time < 30 ms; minimum operating time < 100 ms; dropout to pickup ratio > 98%; Temperature influence: +/- 2.5% from -20 C to +70 C; Weight: Approx. 1.5 kg; Dimensions: 12TE case; cut-out 136.5 x 68.7 mm; installation depth 275 mm; Ordering code: MRR1-(aux L/H)(RS485 R)(housing A/D).
The C&S Electric MRR1 provides: Two-stage rotor earth fault (warning RW and trip R<), exciter DC undercurrent (Ie<), exciter DC overcurrent (Ie>) and rotating diode failure by ripple detection (Ir).
The C&S Electric MRR1 covers ANSI device codes 37 (DC undercurrent), 40 (field relay), 58 (rectification failure), 64 (ground detector), 76 (DC overcurrent).
Standards and compliance for the C&S Electric MRR1: IEC 60255 series.
Yes, the C&S Electric MRR1 (Numeric Rotor Earthfault Protection Relay) is listed on VendorStocks. Add it to your cart and choose “Continue to Buy”, or contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in for a quotation, bulk quantities and delivery to your site in India.
You can buy C&S Electric protection relays online on VendorStocks, the B2B electrical marketplace from Skylights Energy, Bangalore. The VendorStocks team can help with relay selection.
Yes, VendorStocks takes bulk and project-quantity orders for the C&S Electric MRR1. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your required quantity for a quotation on the full quantity and delivery to your site or panel manufacturing unit.
Yes. Contact VendorStocks at +91 99021 83031 or support@skylightsenergy.in with your quantity for a formal quotation on the C&S Electric MRR1, or add it to your cart and choose “Continue to Buy” to order directly. For a project with several items, email your BOM (Bill of Materials) to support@skylightsenergy.in for a single consolidated quote.
Yes, the C&S Electric datasheet for the MRR1 can be downloaded from the Documents section of this product page.
Online payments on VendorStocks are processed securely through Razorpay. The payment options available for your order are shown at checkout.
C&S Electric - CSEZen-F300 - Numerical Multifunction Feeder Relay F300
RFQ

C&S Electric - CSENEX-I101/150/350 - HI TECH Numerical Multifunction Feeder Relay
RFQ

C&S Electric - CSEPRO-M200 - Numerical Multifunction Motor Relay M200
₹55,000excl. GST₹64,900 incl. 18% GST

C&S Electric - CSE-NEX-I-202 - 3 O/C + 1 E/F Relay with Hi-Set & Autorecloser, 6 DI
RFQ

C&S Electric - MRF2 - Numeric Multistage Frequency Relay
₹70,000excl. GST₹82,600 incl. 18% GST

C&S Electric - CSEZen-F550x - Advance Multifunction Feeder Protection Relay F550x
RFQ
Pay by UPI, card or net banking through a PCI-DSS compliant payment gateway (Razorpay). Card and UPI details are never stored on VendorStocks.
Delivered anywhere in India, straight from the seller's warehouse. Shipping is calculated at checkout from your delivery pincode and the item's weight.
Returns, replacements and warranty claims are handled by the seller under the manufacturer's policy and dealership terms. See our Return & Refund Policy.
Your cart is empty
New Account
Create your account to continue
Already have an account?
Welcome back
Sign in to continue
Don't have an account?